4.6 Review

Non-Contact Infrared Thermometers and Thermal Scanners for Human Body Temperature Monitoring: A Systematic Review

期刊

SENSORS
卷 23, 期 17, 页码 -

出版社

MDPI
DOI: 10.3390/s23177439

关键词

body temperature; infrared thermometer; thermal scanner; infrared camera; non-contact thermometer

向作者/读者索取更多资源

Non-contact infrared thermometers (NCITs) and infrared thermography (IRT) have been widely used as convenient and non-invasive tools for measuring human body temperature. However, their accuracy under different conditions remains a question. In this systematic review, evidence from 32 studies with a total of 72 unique settings was synthesized to critically evaluate the performance of NCITs and IRT in body temperature monitoring. The primary findings indicate that NCITs and IRT can provide accurate and reliable measurements in specific settings and conditions, with NCITs showing slightly better accuracy than IRT.
In recent years, non-contact infrared thermometers (NCITs) and infrared thermography (IRT) have gained prominence as convenient, non-invasive tools for human body temperature measurement. Despite their widespread adoption in a range of settings, there remain questions about their accuracy under varying conditions. This systematic review sought to critically evaluate the performance of NCITs and IRT in body temperature monitoring, synthesizing evidence from a total of 72 unique settings from 32 studies. The studies incorporated in our review ranged from climate-controlled room investigations to clinical applications. Our primary findings showed that NCITs and IRT can provide accurate and reliable body temperature measurements in specific settings and conditions. We revealed that while both NCITs and IRT displayed a consistent positive correlation with conventional, contact-based temperature measurement tools, NCITs demonstrated slightly superior accuracy over IRT. A total of 29 of 50 settings from NCIT studies and 4 of 22 settings from IRT studies achieved accuracy levels within a range of & PLUSMN;0.3 & DEG;C. Furthermore, we found that several factors influenced the performance of these devices. These included the measurement location, the type of sensor, the reference and tool, individual physiological attributes, and the surrounding environmental conditions. Our research underscores the critical need for further studies in this area to refine our understanding of these influential factors and to develop standardized guidelines for the use of NCITs and IRT.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据