4.6 Article

Comparison of Microwave Hyperthermia Applicator Designs with Fora Dipole and Connected Array

期刊

SENSORS
卷 23, 期 14, 页码 -

出版社

MDPI
DOI: 10.3390/s23146592

关键词

microwave hyperthermia; cancer therapeutics; fractal octagonal ring array; dipole antenna; connected array; particle swarm optimization

向作者/读者索取更多资源

This study investigates the potential of using fractal octagonal ring antenna elements for breast tumor hyperthermia therapy at 2.45 GHz. Simulation and optimization of antenna excitation parameters are performed to obtain the specific absorption rate distributions for different antenna array designs. The results show that the dipole fractal octagonal ring antenna array has superior performance and feasibility in microwave hyperthermia for breast tumors.
In microwave hyperthermia tumor therapy, electromagnetic waves focus energy on the tumor to elevate the temperature above its normal levels with minimal injury to the surrounding healthy tissue. Microwave hyperthermia applicator design is important for the effectiveness of the therapy and the feasibility of real-time application. In this study, the potential of using fractal octagonal ring antenna elements as a dipole antenna array and as a connected array at 2.45 GHz for breast tumor hyperthermia application was investigated. Microwave hyperthermia treatment models consisting of different fractal octagonal ring antenna array designs and a breast phantom are simulated in COMSOL Multiphysics to obtain the field distributions. The antenna excitation phases and magnitudes are optimized using the global particle swarm algorithm to selectively increase the specific absorption rate at the target region while minimizing hot spots in other regions within the breast. Specific absorption rate distributions, obtained inside the phantom, are analyzed for each proposed microwave hyperthermia applicator design. The dipole fractal octagonal ring antenna arrays are comparatively assessed for three different designs: circular, linear, and Cross-array. The 16-antenna dipole array performance was superior for all three 1-layer applicator designs, and no distinct difference was found between 16-antenna circular, linear, or cross arrays. Two-layer dipole arrays have better performance in the deep-tissue targets than one-layer arrays. The performance of the connected array with a higher number of layers exceeds the performance of the dipole arrays in the superficial regions, while they are comparable for deep regions of the breast. The 1-layer 12-antenna circular FORA dipole array feasibility as a microwave hyperthermia applicator was experimentally shown.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据