4.6 Article

Continuous Glucose Monitoring: A Possible Aid for Detecting Hypoglycemic Events during Insulin Tolerance Tests

期刊

SENSORS
卷 23, 期 15, 页码 -

出版社

MDPI
DOI: 10.3390/s23156892

关键词

hypopituitarism; glucose-monitoring system; hypoglycemia; growth hormone deficiency

向作者/读者索取更多资源

The combined pituitary function test evaluates the anterior pituitary gland and the insulin tolerance test evaluates growth hormone deficiencies. Close medical supervision and glucose monitoring are required during hypoglycemia induction, making the test tedious. Continuous glucose monitoring can be used as a safe aid for clinicians during insulin tolerance tests where critical hypoglycemia is induced.
The combined pituitary function test evaluates the anterior pituitary gland, while the insulin tolerance test evaluates growth hormone deficiencies. However, successful stimulation requires achieving an appropriate level of hypoglycemia. Close medical supervision for glucose monitoring is required during hypoglycemia induction and the test is often very tedious. In addition, a capillary blood sugar test (BST) and serum glucose levels may differ greatly. An alternative approach may be utilizing a continuous glucose-monitoring (CGM) system. We provide three cases in which CGM was successfully used alongside a standard BST and serum glucose levels during the combined pituitary function test to better detect and induce hypoglycemia. Three participants who were diagnosed with multiple pituitary hormone deficiencies during childhood were re-evaluated in adulthood; a Dexcom G6 CGM was used. The CGM sensor glucose and BST levels were simultaneously assessed for glycemic changes and when adequate hypoglycemia was reached during the combined pituitary function test. The CGM sensor glucose, BST, and serum glucose levels showed similar glucose trends in all three patients. A Bland-Altman analysis revealed that the CGM underestimated the BST values by approximately 9.68 mg/dL, and a Wilcoxon signed-rank test showed that the CGM and BST measurements significantly differed during the stimulation test (p = 0.003). Nevertheless, in all three cases, the CGM sensor mimicked the glycemic variability changes in the BST reading and assisted in monitoring appropriate hypoglycemia nadir. Thus, CGM can be used as a safe aid for clinicians to use during insulin tolerance tests where critical hypoglycemia is induced.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据