4.7 Article

Experimental study on the atomization characteristics and dust removal efficiency of a fan-shaped nozzle for purifying working environment

期刊

SCIENCE OF THE TOTAL ENVIRONMENT
卷 894, 期 -, 页码 -

出版社

ELSEVIER
DOI: 10.1016/j.scitotenv.2023.164994

关键词

Atomization characteristic; Fan -shaped nozzle; Phase -Doppler Anemometer; Spray dust removal; Dust removal efficiency

向作者/读者索取更多资源

This study designed 88 measuring points using a 3D Fiber Phase-Doppler Anemometer to reveal the spatial distribution characteristics of atomization parameters of a fan-shaped pressure atomization nozzle. The results showed that the spatial distribution of atomization parameters in the axis and radial direction of the nozzle was inhomogeneous. The increase of spray pressure can improve atomization performance and dust removal efficiency to a certain extent, but the improvement effect had a limit. The findings provide reference for the design and operation of a spray system.
The inadequacy of the existing research in characterizing the atomization performance of the whole atomization field by the local region at nozzle axis hinders the improvement of dust removal performance of a spray system, especially for fan-shaped nozzles with large atomization angle. To solve this inadequacy, 88 measuring points were designed in this study to reveal the spatial distribution characteristics of atomization parameters of a fan-shaped pressure atomization nozzle using a 3D Fiber Phase-Doppler Anemometer. Moreover, the atomization performance and dust removal performance of the whole atomization field under different spray pressures were characterized. The results showed that the spatial distribution of atomization parameters in the axis and radial direction of the nozzle was inhomogeneous. As the axial distance from the nozzle outlet increased, the average droplet size showed a trend of first decreasing and then increasing, the proportion of the droplet of 15-70 & mu;m showed a trend of first increasing and then decreasing, while the average droplet velocity and droplet flux showed a decreasing trend. In addition, the spray orientation was perpendicular to gravity, and the atomization field was parallel to gravity, resulting in a significant difference in the average droplet size between the upper region and the axis. Compared with the upper and lower regions, the atomization effect at the axis was superior, manifested by higher average droplet velocity and droplet flux, indicating that characterizing nozzle atomization performance with atomization parameters at the axis will lead to overestimation. The increase of spray pressure can improve atomization performance and dust removal efficiency to a certain extent, but the improvement effect had a limit. The atomization field can be divided into atomization region, expansion region and contraction region, and the expansion region was considered as an effective dust removal region. These findings provide reference for the design and operation of a spray system.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。