In this paper, a novel hybrid demand response program (DRP) and energy management strategy (EMS) are proposed to improve the efficiency of power systems. The hybrid DRP combines time-of-use and incentive-based methods, while the EMS utilizes variations in grid tariff to charge the energy storage system at low cost. The results of a case study show that the hybrid DRP reduces peak demand and energy cost, and the EMS further decreases the cost.
Over the last two decades, there has been a significant interest in developing solutions to improve the efficiency of power systems, such as optimal energy consumption and management. The demand response programs (DRP) have long been one of the most effective strategies to encourage consumers to change their consumption behavior. In this paper, a novel hybrid DRP has been implemented by combining the time of use (TOU) and incentive-based (IB) DRP methods. To meet the load demand, a PV-WT-BESS hybrid renewable energy system (HRES) has been proposed in this work. Further, to analyze the impact of hybrid DRP on the capacity allocation of different system components, optimal sizing has been performed in two scenarios, one with the actual load and the second with the load after considering the hybrid DRP. The optimization has been carried out by using an improved search space reduction (ISSR) algorithm. To demonstrate the effectiveness of the ISSR algorithm, the obtained results are compared with other algorithms such as particle swarm optimization (PSO), grey wolf optimization (GWO), teaching-learning based algorithm (TLBO), seagull optimization algorithm (SOA), and sine cosine algorithm (SCA). Finally, a novel energy management strategy (EMS) is also proposed in this work on the supply side of the HRES, which intelligently uses the variations in the grid tariff to charge the BESS when the tariff is low. To demonstrate the proposed DRP and EMS-based sizing, a case study has been performed for a grid-connected PV-WT-BESS for the location of Kanyakumari, India. From the results obtained, it has been concluded that the hybrid DRP reduces the peak demand up to 5%, which reduces the levelized cost of energy (LCE) by 22%. Furthermore, the proposed novel EMS reduces the LCE further by 5%. The overall cost reduction of up to 25% has been achieved by using both the proposed hybrid DRP and EMS, while satisfying all necessary constraints.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据