4.7 Article

FLASH radiotherapy using high-energy X-rays: Current status of PARTER platform in FLASH research

期刊

RADIOTHERAPY AND ONCOLOGY
卷 190, 期 -, 页码 -

出版社

ELSEVIER IRELAND LTD
DOI: 10.1016/j.radonc.2023.109967

关键词

FLASH radiotherapy; Megavoltage X-ray; PARTER platform; Beam monitoring; Dosimetry

向作者/读者索取更多资源

This paper provides a comprehensive description of the current status of PARTER, which is the first experimental FLASH platform utilizing megavoltage X-rays. It showcases the reliable performance and stability of the dosimeters and monitors used in PARTER, as well as the satisfactory dose distribution and characteristics of the FLASH X-rays. The platform effectively meets the requirements of preclinical research on megavoltage X-ray FLASH and undergoes continuous upgrades.
Purpose: Recent studies indicated that ultrahigh dose rate (FLASH) radiation can reduce damage to normal tissue while maintaining anti-tumour activity compared to conventional dose rate (CONV) radiation. This paper provides a comprehensive description of the current status of the Platform for Advanced Radiotherapy Research (PARTER), which serves as the first experimental FLASH platform utilizing megavoltage X-rays and has facilitated numerous experiments. Methods and Materials: PARTER was established in 2019 based on a superconducting linac to support experimental FLASH studies using megavoltage X-rays. Continuous upgrades have been made to the accelerator, collimators, flattening filters, monitors, other auxiliary devices, and irradiation process in order to achieve optimal results. Passive and active dosimeters are employed for measuring dose distribution and to ensure traceability of radiation doses. Results: The dose monitors and dosimeters demonstrate reliable performance with acceptable stability. At PARTER, the maximum mean dose rate is approximately 400 Gy/s at a surface-source distance of 20 cm (over 1000 Gy/s at smaller distances), with an instantaneous dose rate of approximately 8E5 Gy/s. Both passive and active dosimeters exhibit good linearity and agreement during FLASH X-ray irradiation. The monitors show good linearity to dose rate, with short-term fluctuations within 1.5 % for the diamond monitor. The discrepancy between measured absorbed dose and dose protocol is typically less than 4 %. The X-ray energy spectra on PARTER are comparable to those for megavoltage CONV linacs operating in flattening filter-free mode. The maximum field size of the FLASH beam is 4.5 cm x 4.5 cm. The FLASH dose profile demonstrates satisfactory flatness (1.04) and similar penumbra compared to clinical CONV linac, while the percentage depth dose curve of FLASH X-rays is steeper than that of the clinical megavoltage CONV X-ray. Conclusions: PARTER represents a pioneering platform for conducting megavolts FLASH X-ray irradiation in biological experiments. It effectively fulfills the requirements of preclinical research on megavoltage X-ray FLASH and undergoes continuous upgrades to meet increasingly demanding performance criteria.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据