A novel process of acid leaching neutralization was developed for the preparation of inorganic polymeric composite ferric aluminum silicate coagulant (CFAS) using solid waste coal gasification coarse slag (CGCS). The optimized preparation process was determined through single-factor experiment and the performance of CFAS was evaluated for domestic sewage treatment. The results showed that CFAS exhibited excellent coagulation ability and achieved significant removal efficiency for turbidity, ammonia nitrogen, and chemical oxygen demand.
A novel process of acid leaching neutralization was initiated for the preparation of inorganic polymeric com-posite ferric aluminum silicate coagulant (CFAS) based on the reutilization of solid waste coal gasification coarse slag (CGCS). Firstly, a single-factor experiment was carried out to optimize the preparation process by adjusting pH, polymerization time and maturation temperature. The results proved that the coagulant of CFAS was ach-ieved under the optimal conditions of pH 3.0, polymerization reaction time 120 min and the maturation tem-perature of 80 degrees C. CFAS was further characterized by X-ray Fluorescence Spectrometry (XRF), X-ray diffraction (XRD), Fourier Transform Infrared Spectroscopy (FTIR), and Scanning Electron Microscope (SEM). It was found that CFAS was mainly occupied with Si, Fe, Ca, and Al. Secondly, the performance of CFAS was evaluated by domestic sewage, and the results indicated the best removal efficiency of turbidity of 93.8%, ammonia nitrogen (NH4-N) of 94.8%, and chemical oxygen demand (COD) of 63.9% were achieved when the dosage of CFAS was 150.0 mg/L, initial pH of domestic sewage was 3.0, and the initial temperature was 30 degrees C, which were further investigated by response surface methodology (RSM), it was found that the temperature played a greater role in the coagulation process, followed by dosage coagulant and pH. Additionally, the coagulation mechanisms demonstrated that the charge neutralization dominated the coagulation process, affiliated by adsorption bridge, and sedimentation netting based on the microscope image of CFAS, the variation of zeta potential and particle size of flocs.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据