4.3 Article

Subsequent Device Usage and Caregiver Attitudes to Do-It-Yourself Real-Time Continuous Glucose Monitoring (DIY-rtCGM) among Children with Type 1 Diabetes 3 Months after Participation in a Randomized Controlled Trial

期刊

PEDIATRIC DIABETES
卷 2023, 期 -, 页码 -

出版社

WILEY-HINDAWI
DOI: 10.1155/2023/3435944

关键词

-

向作者/读者索取更多资源

This study assessed the subsequent device usage and caregiver attitudes towards do-it-yourself real-time continuous glucose monitoring (DIY-rtCGM) at least 3 months after completing a randomized controlled trial (RCT). Results showed that more than half of the families had stopped using DIY-rtCGM, with 40% of them switching to commercial rtCGM. While overall perceptions of DIY-rtCGM remained positive, the burdens of use were high and contributed to discontinuation.
Aim. To assess children's subsequent device usage and caregiver attitudes to do-it-yourself real-time continuous glucose monitoring (DIY-rtCGM) at least 3 months after completing a randomized controlled trial (RCT). Methods. A brief online questionnaire or telephone call was used to collect the subsequent device usage and caregivers' attitudes from a total of 55 families at least 3 months after their completion of an RCT investigating DIY-rtCGM adapted from their preexisting intermittently scanned glucose sensors plus education on using DIY-rtCGM system. To be eligible for the RCT, children had to be aged 2-13 years, have type 1 diabetes & GE;6 months, and be rtCGM naive. Data collected investigated current CGM use post-RCT and attitudes/user experiences to DIY-rtCGM in the months since RCT study support ended. Results. Overall, responses from 81.8% (45/55) of caregivers were received. Mean age of children was 9.0 & PLUSMN; 2.7 years, and 31 (68.9%) children used insulin pumps. After 3 months, 44.4% (20/45) of responding caregivers reported ongoing DIY-rtCGM use, and of these, only 13 used DIY-rtCGM as the primary glucose monitoring method 100% of time. Of the 25 (55.6%) families who ceased DIY-rtCGM, 40% (10/25) had transitioned to commercial rtCGM. More than half of families (60%, 12/20) who continued DIY-rtCGM use had a very or extremely positive attitude toward the technology and 75% (15/20) of these families planned to continue DIY-rtCGM use. However, signal loss and sensor inaccuracy remained the major reasons among all responders both for decreased DIY-rtCGM wear time and eventual cessation. Burden of use primarily related to technical errors that could not be solved, and alarms, both of which were reported to contribute to discontinuation. Conclusions. This study highlights that, among families voluntarily using DIY-rtCGM at least 3 months following support from a trial, more than half have ceased using DIY-rtCGM, with 40% of those discontinuing switching to commercial rtCGM. While overall perceptions of DIY-rtCGM remain largely positive, burdens of use are high and contribute to discontinuation.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.3
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据