4.7 Article

Assessment of external calibration, internal standard calibration and quadruple isotope dilution strategies for the determination of acrylamide in wastewater samples after LC-MS/MS quantification

期刊

MICROCHEMICAL JOURNAL
卷 190, 期 -, 页码 -

出版社

ELSEVIER
DOI: 10.1016/j.microc.2023.108741

关键词

Acrylamide; Quadruple isotope dilution; Wastewater; LC-MS; MS

向作者/读者索取更多资源

Acrylamide, a potentially neurotoxic and carcinogenic compound, is commonly found in environmental bodies due to industrial usage. This study compared different calibration strategies and proposed a highly accurate and precise method, LC-ID4-MS/MS, to quantify acrylamide in wastewater samples. The ID4 strategy showed superior accuracy and precision compared to EC and ISC methods.
Acrylamide is a possible neurotoxicant and carcinogen compound and its common usage in various industrial processes causes acrylamide contamination in environmental bodies. For this purpose, there is an increasing demand to develop an accurate and selective analytical method for the determination of acrylamide. In the scope of this study, external calibration (EC), internal standard calibration (ISC) and quadruple isotope dilution (ID4) strategies were compared to each other in terms of accuracy and precision. After the evaluation of these methods, liquid chromatography - quadruple isotope dilution - tandem mass spectrometry (LC-ID4-MS/MS) as a highly accurate and precise analytical approach was proposed to quantify acrylamide in wastewater samples. Several parameters for LC system such as sample injection volume, mobile phase type/composition and mobile phase flow rate were elaborately optimized to enhance peak shape and signal to noise ratio (S/N) belonging to the analyte. Under the optimum chromatographic and mass determination conditions, system analytical perfor-mance study was performed to determine dynamic range and limit of detection/quantitation (LOD and LOQ). LOD and LOQ values of the proposed LC-MS/MS method for the analyte were calculated as 1.18 and 3.93 mu g/kg; respectively. After the system analytical performance study, the spiking experiments in wastewater samples were carried out for the evaluation of accuracy and applicability of LC-MS/MS method. For wastewater samples, percent recovery results with their percent relative standard deviations (%RSD) obtained from EC, ISC and ID4 strategies were 115.8-177.8% (+/- 1.2-11.4%), 94.5-117.7% (0.3-4.7%) and 99.6-100.9% (0.4-1.7%); respec-tively. These results prove the superiority of ID4 strategy with regards to accuracy and precision of the results.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据