4.7 Article

Development of polymer films and biological matrices standards for selenium, mercury and endogenous elements quantitative LA-ICP MS imaging in entire rainbow trout fry

期刊

MICROCHEMICAL JOURNAL
卷 194, 期 -, 页码 -

出版社

ELSEVIER
DOI: 10.1016/j.microc.2023.109204

关键词

LA-ICP MS; Bioimaging; Selenium; Mercury; Quantification; Trout fry

向作者/读者索取更多资源

The quantitative imaging of trace elements in biological samples can provide information on their assimilation pathways and help understand their toxicity or essentiality. This study developed two quantitative LA-ICP MS methods and applied them to the imaging of Se, Hg, Cu, Zn, and Mo in rainbow trout. The results showed that the polymer films method provided more accurate quantification compared to the MMS method.
The quantitative imaging of trace elements in biological samples can bring information on their assimilation pathways and help understanding their toxicity or essentiality. This study presents the development of two quantitative LA-ICP MS methodologies and their comparison for Se, Hg, Cu, Zn and Mo imaging in rainbow trout. The first method is based on spiked polymer films (dextran) allowing internal standardization with Ge and Te. The second method relies on the matrix-matched standards (MMS) methodology, with homogenized and spiked trout muscle and calf liver. For Se, Cu, Zn and Mo, linear regressions with correlation coefficient above 0.994 were obtained by LA-ICP MS analysis for both methods. For Hg, only MMS calibration provided linear regression as polymer films exhibited Hg unstable signals during LA-ICP MS analysis. Element concentrations spiked in muscle and liver MMS were also confirmed by ICP MS and used to validate the polymer films method as values obtained for Se, Hg, Mo and Cu were in good agreement. While LODs of polymer film method were in the range of 0.06-0.6 & mu;g.g � 1 for Cu, Se, Mo, and 5 & mu;g.g � 1 for Zn, values were higher for MMS method (from 0.06 (Mo) to 2.2 (Cu) & mu;g.g � 1, and 30 of & mu;g.g � 1 for Zn). Particular attention has been paid to sample embedding and water was found to minimize internal standard response bias. Both methods were then applied to the quantitative mapping of these five elements in rainbow trout fry supplemented or not with organic forms of Se and Hg through parental and direct feeding. Calibrations were analysed before and after sample imaging evidencing a lower bias between the two quantifications with polymer films calibration than with MMS calibration. For the first time, elements concentrations were determined at 60 x 60 & mu;m spatial resolution in specific tissues or organs of entire fry. Depending on the element, polymer films quantification was in agreement with trout muscle (Cu, Se) or with calf liver MMS quantification (Zn).

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据