A mid-infrared interference-free laser absorption technique was developed to simultaneously measure rotational temperature, vibrational temperature, and CO concentration. The technique was validated and showed high sensitivity in detecting temperature and CO concentration in non-equilibrium conditions. The measurement of CO concentration at ultra-high temperatures is significant for research on scramjet engines.
A mid-infrared interference-free laser absorption technique for simultaneously measuring rotational temperature, vibrational temperature, and CO concentration was developed for application to shock-tube studies on thermochemical non-equilibrium CO over 1000-3000 K. Three transition lines in the fundamental vibrational band of CO (P(0, 21), near 4.87 mu m, P(1, 21), near 4.93 mu m, and P(0, 37), near 5.05 mu m) were selected. The P(0, 21)/P(1, 21) line pair was used for vibrational temperature measurements whereas the P(0, 21)/P(0, 37) line pair was used for rotational temperature measurements. Spectroscopic parameters for developing the technique were measured: line strengths and collisional broadening data in Ar were obtained at 1040-2940 K. Validation experiments for the thermometry system were performed in shock-heated thermal-equilibrium CO/Ar mixtures at 1050-3010 K and 1.1-2.8 bar. The time-dependent rotational and vibrational temperatures were measured during the vibrational relaxation processes of CO. The technique showed high sensitivity in detecting the rotational and vibrational temperatures. The measured rotational temperature agreed well with the temperature calculated using the measured pressure and isentropic relationship. The measured vibrational temperature showed good agreement with the predictions using the Landau and Teller theory and Millikan and White relationship. The time-dependent CO concentration during the oxidation processes of n-heptane over a wide temperature range (1350-2750 K) was measured considering n-heptane as one of the alternative fuels for the scramjet. The interference-free laser absorption strategy showed good flexibility in detecting the CO concentration at ultra-high temperatures. The measured results showed overall good agreement with the predictions from two detailed mechanisms and one skeletal mechanism. The reactivity of n-heptane was found to be insensitive to the temperature increase at ultra-high temperatures (> 2100 K).

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据