4.5 Article

Open and endovascular reinterventions after Candy Plug false lumen embolization of type B aortic dissection

期刊

JOURNAL OF VASCULAR SURGERY
卷 78, 期 6, 页码 1409-1417

出版社

MOSBY-ELSEVIER
DOI: 10.1016/j.jvs.2023.07.063

关键词

Candy Plug; Aneurysm; Dissection; Thoraco-abdominal aorta; Open repair; Endovascular repair

向作者/读者索取更多资源

This study investigates the types and outcomes of thoracic endovascular aneurysm repair and Candy Plug (CP) implantation for type B aortic dissection. The CP technique is found to be safe and effective, but there is a significant rate of aortic-related reintervention and high rate of major complications in open repair.
Objective: In the majority of patients with chronic type B aortic dissection, there is persistent retrograde flow in the false lumen (FL) through distal re-entry tears. Among several endovascular techniques proposed for FL management, the Candy Plug (CP) technique has gained acceptance with good early results. The aim of this study is to report the types and outcomes of open and endovascular reinterventions and identify mechanisms of procedure failure as well as other causes for reinterventions. Methods: All patients with type B aortic dissection submitted to thoracic endovascular aneurysm repair and CP implantation for FL embolization from January 2016 to December 2022 at our institution were included in this study. The preoperative, intraoperative, and postoperative data of the primary intervention and secondary reinterventions, when performed, were prospectively collected and retrospectively analyzed. Preoperative and postoperative computed to-mography angiography were also analyzed. Results: During the study period, 33 patients were submitted to thoracic endovascular aneurysm repair and CP implantation. Twenty-three patients (69.7%) showed thoracic FL complete thrombosis with aortic stability or positive remodeling at a mean follow-up of 45 +/- 23.1 months. Ten patients (30.3%) underwent aortic reinterventions (male, n 1/4 9; mean age, 60.5 +/- 7.6 years). Of these 10 patients, in four patients, complete thrombosis of the FL was never achieved, leading to ongoing perfusion of the FL, defined as primary failure. The other six patients underwent reinterventions for different causes: two patients, after initial sealing, showed a progressive enlargement of the abdominal FL leading to distal degeneration. One patient showed proximal degeneration, two patients showed a type II thoracoabdominal aortic aneurysm and CP implantation was used as a planned procedure to reduce the extent of the surgical procedure, and one patient had recurrent, intractable back pain despite complete thrombosis of the FL. Reinterventions were open in five cases and endovascular in five. One in-hospital death (postoperative day 27) after a type II thoracoabdominal aortic aneurysm open repair was recorded. In addition, two cases of delayed spinal cord ischemia after open reintervention were recorded: one resulting in permanent paraplegia and one transitory with complete recovery. Conclusions: The CP technique was safe and effective; however, a significant rate of aortic-related reintervention was observed. Several mechanisms led to reinterventions either in terms of primary failure of the CP or subsequent aneurysmal degeneration. Complex reinterventions were often necessary, with a high rate of major complications in case of open repair. Life-long and closer surveillance might be required in these patients.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据