4.6 Article

A multifunctional fluorescence MOF material: Triple-channel pH detection for strong acid and strong base, recognition of moxifloxacin and tannic acid

出版社

ELSEVIER SCIENCE SA
DOI: 10.1016/j.jphotochem.2023.114708

关键词

Metal-organic frameworks; Detection; pH; Antibiotic; Tannic acid; Moxifloxacin

向作者/读者索取更多资源

A luminescent 1D metal-organic framework [Co(apba)2(H2O)2] (1) was synthesized using Hapba as a ligand. Compound 1 exhibited excellent sensing properties, specifically recognizing strong acid-base and weak acid. It is the first MOF-based pH sensor capable of detecting both strong acid-base and weak acid, and it also has the highest sensitivity among all pH fluorescent sensors. Additionally, it can detect antibiotic moxifloxacin and polyphenol compound tannic acid with low detection limits.
A luminescent 1D metal-organic framework [Co(apba)2(H2O)2] (1) was solvothermal synthesized by using 4-(2aminopyrimidine-5-yl)benzoic acid (Hapba) as ligand. 1 showed pronounced sensing properties with triplechannel specific recognition ability for strong acid-base and weak acid. From pH = 3.5 to 2.0, the fluorescence quenching percentage reached 1064 % per pH at 412 nm due to the protonation of -NH2. In the pH region of 3.5-4.5, 1 realizes wavelength-based pH detection depending on the wavelength shift of 30 nm from 412 nm to 382 nm originating from the protonation of nitrogen atom in pyrimidine. In the pH range of 11.5-13.4, the fluorescence quenching percentage reached 2099 % per pH relying on the interaction between OH- and uncoordinated oxygen atom on carboxylate group. This is the first example that a MOF-based pH sensor can detect strong acid-base and weak acid, and their sensitivity to pH is likewise the highest among all pH fluorescent sensors. 1 can also detect antibiotic moxifloxacin (MOX) and polyphenol compound tannic acid (TA) with the limit of detection (LOD) at the 10 ppb level. In the recognition of 1 for MOX, KSV is 2.05 x 105 M-1 (0-100 & mu;M) and LOD reaches 43 nM, which is the first case of a MOF-based MOX sensor so far. The fluorescence response of 1 to TA is also apparent with the KSV value of 7.55 x 105 M-1 (0-0.05 & mu;M) and LOD of 11 nM. This is as well the only instance of MOF material sensing TA to date. Moreover, 1 can continuously track MOX and TA for up to 90 days. The sensing mechanisms of pH, MOX, and TA are also discussed in detail.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据