4.6 Article

A novel electrochemical biosensor based on palladium nanoparticles decorated on reduced graphene oxide-polyaminophenol matrix for the detection and discrimination of mitomycin C-DNA and acyclovir-DNA interaction

出版社

ELSEVIER
DOI: 10.1016/j.jpba.2023.115524

关键词

Electrochemical DNA nanobiosensor; Drug -DNA interaction; Acyclovir; Mitomycin C; Reduced graphene oxide; palladium; nanoparticles; Voltammetry

向作者/读者索取更多资源

The study demonstrates the performance of a newly developed nanomaterial-based biosensor for the analysis of drug-DNA interaction. The nanomaterial-modified sensor showed significantly higher sensitivity compared to the bare electrode. The developed nanobiosensor system provided highly specific determination between the anticancer drug Mitomycin C and the drug Acyclovir by discriminating their interactions with double-stranded DNA.
Both the design of molecules that will interact specifically with DNA and the determination of the mechanism of action of this drug on DNA are important as they allow the control of gene expression. In particular, rapid and precise analysis of this type of interaction is a vital element for pharmaceutical studies. In the present study, a novel reduced graphene oxide/ palladium nanoparticles/ poly(2-amino-4-chlorophenol) (rGO/Pd@PACP) nanocomposite was synthesized by chemical process to modify pencil graphite electrode (PGE) surface. Here, the performance of the newly developed nanomaterial-based biosensor for drug-DNA interaction analysis has been demonstrated. For this purpose, it was determined whether this system, which was developed by selecting a drug molecule (Mitomycin C; MC) known to interact with DNA and a drug molecule (Acyclovir; ACY) that does not interact with DNA, performs a reliable/accurate analysis. Here, ACY was used as a negative control. Compared to bare PGE, the rGO/Pd@PACP nanomaterial modified sensor exhibited 17 times higher sensitivity performance in terms of guanine oxidation signal measured by differential pulse voltammetry (DPV). Moreover, the developed nanobiosensor system provided a highly specific determination between the anticancer drug MC and ACY by discrimination the interactions of these drugs with double-stranded DNA (dsDNA). ACY was also preferred in studies for the optimization of the new nanobiosensor developed. ACY was detected in a concentration as low as 0.0513 & mu;M (51.3 nM) (LOD), and limit of quantification (LOQ) was 0.1711 & mu;M with a linear range from 0.1 to 0.5 & mu;M.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据