4.4 Article

Practical Characterization Strategies for Comparison, Qualification, and Selection of Cell Viability Detection Methods for Cellular Therapeutic Product Development and Manufacturing

期刊

JOURNAL OF FLUORESCENCE
卷 -, 期 -, 页码 -

出版社

SPRINGER/PLENUM PUBLISHERS
DOI: 10.1007/s10895-023-03382-1

关键词

Cell therapy; Cell viability; Image cytometry; High-throughput cell counter; Acridine orange; Propidium iodide; 4 & PRIME;,6-diamidino-2-phenylindole (DAPI)

向作者/读者索取更多资源

Cellular therapy development and manufacturing require consideration of critical quality attributes such as cell count and viability. However, there is currently no guidance on the selection of a fit-for-purpose cell viability detection method. This study presents strategies for the comparison and evaluation of AO/PI and AO/DAPI staining methods to select a suitable cell viability measurement method.
Cellular therapy development and manufacturing has focused on providing novel therapeutic cell-based products for various diseases. The International Organization for Standardization (ISO) has provided guidance on critical quality attributes (CQAs) that shall be considered when testing and releasing cellular therapeutic products. Cell count and viability measurements are two of the CQAs that are determined during development, manufacturing, testing, and product release. The ISO Cell Counting Standard Part 1 and 2 addressed the needs for improving the quality of cell counting results. However, there is currently no guidance on the qualification and selection of a fit-for-purpose cell viability detection method. In this work, we present strategies for the characterization and comparison of AO/PI and AO/DAPI staining methods using the heat-killed (HK) and low temperature/nutrient-deprived (LT/ND) cell death models to evaluate the comparability of cell viability measurements and identify potential causes of differences. We compared the AO/PI and AO/DAPI staining methods using HK and LT/ND-generated dead cells, investigated the staining time effects on cell viability measurements, and determined their viability linearity with different mixtures of live and dead cells. Furthermore, we validated AO/PI and AO/DAPI cell viability measurement with a long-term cell proliferation assay. Finally, we demonstrate a practical example of cell viability measurement comparison using AO/PI and AO/DAPI on antibiotic-selected transduced Jurkat and THP-1 cells to select a fit-for-purpose method for functional genomics screening. The proposed strategies may potentially enable scientists to properly characterize, compare, and select cell viability detection methods that are critical for cellular therapeutic product development and manufacturing.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据