4.7 Article

Prediction and control of elevated temperatures within landfills under aeration and recirculation based on the thermal non-equilibrium model

期刊

JOURNAL OF ENVIRONMENTAL MANAGEMENT
卷 345, 期 -, 页码 -

出版社

ACADEMIC PRESS LTD- ELSEVIER SCIENCE LTD
DOI: 10.1016/j.jenvman.2023.118873

关键词

Landfill; Leachate recirculation; Aeration; Thermal non-equilibrium; Elevated temperatures

向作者/读者索取更多资源

Aeration combined with leachate recirculation is an effective approach for temperature control in landfills. A local thermal non-equilibrium model was developed to predict landfill temperatures during aeration and recirculation. Simulation results showed that assuming local thermal equilibrium overestimated the temperature. The model was used to investigate gas mixtures and operating conditions, providing guidelines for the design of an aeration and recirculation combined system.
Aeration is an effective approach to sustainable landfilling but may lead to elevated temperatures within landfills, resulting in landfill fires or explosions. Therefore, aeration is usually combined with leachate recirculation to control the elevated temperatures within landfills. To predict landfill temperatures during aeration and recirculation, a local thermal non-equilibrium model is developed considering the heat generation of biodegradation, the heat removal due to evaporation and leachate-gas flow, and the effects of the capillary. The solver is implemented in OpenFOAM based on the finite volume method and validated against a waste-column experiment and an in-situ aeration test. The simulation results demonstrate that the assumption of local thermal equilibrium will distinctly overestimate the temperature, maximally by 15 degrees C in the studied case. The model is then used to simulate a typical aerobic landfill unit to investigate the formation of explosive gas mixtures and elevated temperatures under different operating conditions. The simulation results of gas composition suggest that aeration will not result in explosive gas within landfills. A reasonable recirculation method for temperature control with corresponding operating parameters under a group of values of aeration pressure (2000-4000 Pa) and recirculation rate (0.0001-0.0008 m/s) are proposed, which can provide some guides for the design of an aeration and recirculation combined system. For a given total volume of added leachate, a higher recirculation rate does not always mean better cooling, and the cooling effect of continuous recirculation is better than that of intermittent recirculation.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据