4.7 Article

Toward a better understanding of peroxymonosulfate and peroxydisulfate activation using a nano zero-valent iron catalyst supported on graphitized carbon: Mechanisms and application to the degradation of estrogenic compounds in different water matrix

期刊

JOURNAL OF CLEANER PRODUCTION
卷 414, 期 -, 页码 -

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.jclepro.2023.137702

关键词

Advanced oxidation processes; Endocrine disrupting compounds; Fenton -like activation; Ferryl ions; Radical formation

向作者/读者索取更多资源

In this study, nano zero-valent iron catalysts supported on graphitized carbon (GC-nZVI) were used to efficiently degrade BPA under neutral pH conditions. The catalyst showed a significant synergistic effect, increasing the degradation efficiency of BPA under both dark and UVA conditions.
In this study, we employed nano zero-valent iron catalysts supported on graphitized carbon (GC-nZVI) catalyst to efficiently degrade BPA under circumneutral pH conditions in both dark and UVA radiation. The GC-nZVI catalyst was characterized using specific techniques (XPS, FTIR, BET, etc.), and was used to activate both PS and PMS in solution. Although no significant BPA degradation constant (kBPA) was determined using PS/PMS or GC-nZVI alone, a significant synergistic effect was observed in the system. Under dark conditions, kBPA increased from 0.01 min-1 to 0.17 when PS was used, both in the dark and under UVA. Notably, when PMS was present in the system, the improvement was even higher with kBPA reaching 0.18 and 0.26 min-1 under dark and UVA conditions, respectively. To further support the synergistic effect, it was found that 80% of mineralization was achieved within 2 h of UVA exposure. Chemical quenching experiments were conducted using selective probes and kinetic modelling showed that the activation of PS/PMS produced sulfate radicals (SO4 & BULL;- ), hydroxyl radicals (& BULL;OH) and ferryl ions (FeIVO2+) in both systems. Additionally, GC-nZVI/PMS system demonstrated good stability in recycling experiments, with up to 70% of BPA still being degraded after 3 cycled in 1 h under UVA. In conclusion, the degradation efficiencies of GC-nZVI/PMS and GC-nZVI/PS systems under dark and UVA radiation were assessed for three different EDCs (BPA, E2, and EE2) in both tap and sewage treatment plant waters. This study has demonstrated that the highly efficient GC-nZVI/PS/UVA or GC-nZVI/PMS/UVA system has significant potential for application in different water matrix, and our findings provide insights into the design of heterogeneous Fenton-like and photo-Fenton-like catalysts.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据