4.5 Article

Optimization and validation of analytical affinity chromatography for the in-process monitoring and quantification of peptides containing a C-tag

出版社

ELSEVIER
DOI: 10.1016/j.jchromb.2023.123899

关键词

Antimicrobial peptide; C-tag; Protein analysis; high performance liquid chromatography; (HPLC); Affinity chromatography; design of experiments (DoE)

向作者/读者索取更多资源

Antimicrobial peptides and proteins (AMPs) are potential substitutes for antibiotics in treating infections caused by multidrug-resistant bacteria. In this study, a high-throughput analytical immunoaffinity chromatography method was optimized to accurately quantify AMPs containing a C-tag, allowing reliable assessment of product quantity and quality.
Antimicrobial peptides and proteins (AMPs) are promising alternatives to conventional antibiotics for the treatment of infections caused by multidrug-resistant bacteria. The production of recombinant AMPs is facilitated by platform technologies such as the C-tag, a sequence of four C-terminal amino acids that allows immunoaffinity capture and purification. However, the detection and quantification of such products throughout the manufacturing process is a significant challenge. We therefore used a design of experiments approach to optimize a novel high-throughput analytical immunoaffinity chromatography method for the accurate quantification of AMPs containing a C-tag, resulting in minimal analyte carryover (98.8 +/- 0.1 % product elution). We then validated the method in accordance with International Conference on Harmonisation guideline Q2(R2). Validation confirmed that the method achieves high specificity, linearity, accuracy, and precision. We implemented in-process control and quantification throughout the manufacturing process, from cell lysis to the final purified product. We found that the lysate and acidic samples (pH < 2) can lead to deviations. However, following sample pretreatment, C-tag quantification reduced the error to <= 4 %, which is potentially superior to current nonspecific quantification methods such as UV absorbance and colorimetry. Implementing this method for in process control and quantification throughout the manufacturing process achieves the reliable assessment of product quantity and quality. This method also offers improvements over the product-specific enzyme-linked immunosorbent assay currently used for C-tagged products because it has a higher precision, accuracy and throughput, with a measurement time of 2.5 min per sample. Our analytical affinity chromatography method is therefore a valuable tool for the quantification of AMPs as part of a novel platform technology approach for C tagged products.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据