4.5 Article

An improved approach to model compressors, condenser/gas cooler and their control system in refrigeration systems with R404A and R744 based on physical principles

期刊

INTERNATIONAL JOURNAL OF REFRIGERATION
卷 153, 期 -, 页码 127-139

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.ijrefrig.2023.06.024

关键词

Supermarket refrigeration; R744 booster; R404A booster; Condenser/gas cooler modeling; Compressor modeling

向作者/读者索取更多资源

This study introduces an improved methodology to accurately evaluate the performance of a conventional R404A system and a Booster R744 system. The improved modeling and control system enhance the accuracy and performance of the compressors, allowing for a comparison of both systems at different ambient temperatures.
This study introduces an improved methodology to evaluate with accuracy the performance of a conventional system with R404A and a Booster system with R744. Reciprocating and scroll compressors are modeled with improved semi-empirical approaches, and their operation is ideally controlled to maintain the required refrigerant mass flow rate with an On/Off and variable speed control system. The R744 gas cooler is modeled with a four-zones model and the R404A condenser with a three-zones model. The R744 condenser is modeled with the superheated zone discretized into eight zones to avoid unrealistic results due to the variation of its thermo-physical properties and the two-phase and subcooled zones with one zone respectively. In line with the design, the Booster condenser enters into the pseudo-critical zone at an ambient temperature of 23 degrees C, while the gas cooler is activated after 31 degrees C. The compressor models present errors lower than 10%, while the Booster model presents mean deviations lower than 2.3%. The Booster system presents better COPs than the conventional at ambient temperatures lower than 15oC. At higher ambient temperatures, the COPs of both systems are similar: the conventional system overperforms the Booster up to 6%, being in disagree with the literature results where these differences increase up to 30%. The proposed methodology allows to reduce the overall model error by 3% with respect to a thermodynamic cycle-based model; allowing to improve the comparison between the Booster system with R744 and the conventional one with R404A, which leads to more transparent results than the reported common comparisons.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据