An experimental study on gas temperature characteristic in tunnel fires: The influences of sidewall restriction and sealing effect

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.ijheatmasstransfer.2023.124385

关键词

Tunnel fires; Sidewall restriction; Sealing effect; Gas temperature characteristic

向作者/读者索取更多资源

This study provides a comprehensive experimental investigation on the impact of fire source position on gas temperature characteristics during the sealing process. A correlation function between the ceiling maximum gas temperature and transverse fire source position factor and sealing ratio is proposed based on theoretical analysis. Methanol pool fire experiments are conducted in a reduced tunnel, considering different fire source positions and sealing ratios. The results reveal the influence of sidewall restriction and sealing effect on maximum gas temperature and longitudinal distribution pattern.
This work provides a comprehensive experimental study on the influence of fire source position on gas temperature characteristics during the sealing process. A function correlating the ceiling maximum gas temperature and transverse fire source position factor and the sealing ratio was proposed based on the-oretical analysis. Then, a series of methanol pool fire experiments were conducted in a reduced tunnel, considering three fire source positions and five sealing ratios, to investigate the influence of sidewall re-striction and sealing effect on the maximum gas temperature and longitudinal distribution pattern. The results demonstrate that the maximum gas temperature does not increase continuously as the fire source moves toward the sidewall. There exists a position in which the lowest gas temperature beneath the ceil-ing is generated as a result of the combined effect of the flame on air entrainment and the enhanced radiation of the flame to the sidewall. Moreover, the maximum gas temperature rise is found to linearly increase with the sealing ratio and vary as a quadratic function of the transverse fire source position factor. Finally, the calculation model for the longitudinal distribution pattern of ceiling gas temperature rise is developed, which can provide reasonable predictions for different fire scenarios considering fire locations, sealing ratios as well as fire sizes.& COPY; 2023 Published by Elsevier Ltd.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据