4.4 Article Proceedings Paper

Improved capacitive detection method for Coriolis mass flow sensors enabling range/sensitivity tuning

期刊

MICROELECTRONIC ENGINEERING
卷 159, 期 -, 页码 1-5

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/j.mee.2016.01.029

关键词

Coriolis flow sensor; Capacitive readout; Phase detection; Actuation mode cancelation

向作者/读者索取更多资源

We report on a novel capacitive detection principle for Coriolis mass flow sensors which allows for three times increased sensitivity. Capacitive Coriolis mass flow sensors are normally read out by two electrodes that measure the ratio between the actuation mode and the Coriolis mode, which is induced by the mass flow. This ratio results in a phase shift between the two electrodes. By adding two additional read out electrodes, the actuation mode signal is partially canceled, allowing for higher sensitivity to the Coriolis mode, and thus larger phase shifts for the same mass flows. An analytical model is derived and corresponds with the measurements. It is also proven that the range and sensitivity ofthe sensor can be tuned by changing the size of the additional readout electrodes. This readout method does not increase the readout time. (C) 2016 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据