4.3 Article

Efficient and cost-effective determination of Cr(VI) ions using immobilized 4,5-dihydroxynaphthalene-2,7-disulfonic acid disodium salt dihydrate: a novel analytical reagent with high selectivity and sensitivity

出版社

TAYLOR & FRANCIS LTD
DOI: 10.1080/03067319.2023.2235562

关键词

4; 5-dihydroxynaphthalene-2; 7-disulfonic acid; PDA polymer; immobilization; Cr(VI) determination; analytical reagent; >

向作者/读者索取更多资源

This study introduces a time-saving, cost-effective, selective, highly efficient and eco-friendly analytical reagent for detecting Cr(VI) ions. The immobilised DHNDSADNa on the PPA matrix is a highly selective, accurate, easily regenerable, and rapid analytical reagent for the determination of Cr(VI) ions. The reagent exhibits high selectivity and efficiency for Cr(VI) ions and shows superior analytical characteristics compared to previously utilised methods.
The determination of Cr(VI) ions in real-world samples is of utmost importance due to the critical role it plays in assessing and monitoring the levels of Cr(VI) contamination in water. The present study introduces a time-saving, cost-effective, selective, highly efficient and eco-friendly analytical reagent to detect Cr(VI) ions. This study presents fabrication of immobilised 4,5-dihydroxynaphthalene-2,7-disulfonic acid disodium salt dihydrate (DHNDSADNa) on a polyethylene-polyamine polyacrylonitrile (PPA) matrix for the determination of Cr(VI) ions using X-ray fluorescence, spectroscopic analysis and potentiodynamic titration methods. The findings revealed that the immobilised DHNDSADNa on the PPA matrix is a highly selective, accurate, easily regenerable, and rapid analytical reagent for the determination of Cr(VI) ions. The DHNDSADNa-anchored PPA framework demonstrated distinctive spectroscopic signals at 460 nm and 590 nm for the reagent and its complex with Cr(VI) ions, respectively. The detection limit for Cr(VI) ions was found to be 2 & mu;g/mL, which is lower than that of DHNDSADNa in solution. Furthermore, the reagent exhibited high selectivity and efficiency for Cr(VI) ions even in the presence of other ions such as Co(II), Ni(II), Al(III), Fe(II), Ti(IV), Zr(IV), Ta(V), Mn(II), and W(VI). Last but not least, the immobilised DHNDSADNa on the PPA matrix exhibits superior analytical characteristics compared to previously utilised methods, making it a promising tool for various applications in medicine, pharmacology, biology, chemistry, and engineering.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.3
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据