Long-term outcomes of patients treated with sirolimus-eluting resorbable magnesium scaffolds: Insights from the SHERPA-MAGIC study

期刊

INTERNATIONAL JOURNAL OF CARDIOLOGY
卷 383, 期 -, 页码 1-7

出版社

ELSEVIER IRELAND LTD
DOI: 10.1016/j.ijcard.2023.04.029

关键词

Resorbable magnesium scaffold; Percutaneous coronary intervention; Outcome; Vessel oriented cardiac event

向作者/读者索取更多资源

This study investigated the safety and long-term effectiveness of resorbable magnesium scaffold (RMS) in a narrowly selected population. After a minimum follow-up of 1 year, the occurrence of vessel-oriented composite endpoints (VOCE) was significantly lower than expected. Patient-level analysis confirmed the findings of the vessel-level analysis. These results confirm the safety and performance of RMS technology.
Background: The resorbable magnesium scaffold (RMS) is a second-generation bioresorbable scaffold (BRS) that has shown conflicting results in previous studies. These findings suggest that patient selection and implantation technique may have an impact on clinical outcomes. This study aimed to investigate the safety and long-term effectiveness of RMS in a narrowly selected population. Methods: SHERPA-MAGIC is an investigator-driven, multicenter, prospective, single-arm study that enrolled patients undergoing BRS coronary implantation in 18 Italian centers. The present analysis considered the first 543 enrolled patients treated with RMS, with a minimum follow-up of 1 year. The study protocol included strict criteria for patient selection and standardization of RMS implantation. The primary outcome was the occurrence of the vessel-oriented composite endpoints (VOCE), including cardiac death, target vessel myocardial infarction, and ischemia-driven target vessel revascularization. Results: Overall, 635 vessels were treated. The 1-year cumulative occurrence of VOCE was 22 (3.5%, 95% CI 2.2%-5.2%), which was significantly lower than the prespecified estimation (from 5.5% to 8.5%). At the median follow-up of 3.5 [2.6-4.3] years, there were 3 (0.5%) cardiac deaths, 12 (1.9%) target vessel myocardial infarctions, and 33 (5.2%) ischemia-driven target vessel revascularizations. A total of 37 (5.8%, 95%CI 4.1%- 7.9%) VOCEs were detected. Scaffold thrombosis occurred in 4 (0.6%, 95%CI 0.1%-1.6%) cases. Patient-level analysis confirmed the findings of the vessel-level analysis. Conclusions: These results confirm the safety and performance of RMS technology. If confirmed in randomized controlled trials, they may rekindle interest in the use of scaffolds in daily practice.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据