A Simple Technique Linearizing and Decoupling DC-Link Voltage Control From Source Nonlinearity in Single-Stage Photovoltaic Inverters

期刊

IEEE TRANSACTIONS ON POWER ELECTRONICS
卷 38, 期 9, 页码 11652-11663

出版社

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/TPEL.2023.3290958

关键词

Cascaded control; dc-ac power conversion; photovoltaic (PV) power systems; photovoltaic voltage control; transient response

向作者/读者索取更多资源

This article investigates the influence of nonlinear behavior of photovoltaic (PV) sources on the dc voltage regulation of single-stage single-phase grid-connected inverters. The analysis reveals two issues: undesired strong coupling between regulation transient performance and PV source operating point, and possible instability arising when the PV source operates on the left-hand side of its maximum power point (MPP). To solve these problems, the idea to add the PV power feedforward signal to the output of the dc voltage controller is proposed, resulting in improved PV voltage regulation performance and stable dc voltage control dynamics.
The nonlinear behavior of photovoltaic (PV) sources can deteriorate the performance of PV inverters if their control system is not designed carefully. This article investigates the PV source influence on the dc voltage regulation of single-stage single-phase grid-connected inverters. The analysis reveals two issues: undesired strong coupling between regulation transient performance and PV source operating point, and possible instability arising when the PV source operates on the left-hand side of its maximum power point (MPP). To eradicate these issues, the idea to add the PV power feedforward signal to the output of the dc voltage controller is applied. This action cancels the nonlinearity induced by the source, responsible for poor PV voltage regulation performance, resulting in large-signal linear and stable dc voltage control dynamics. The benefit is twofold. First, the dc voltage transient response is desirably decoupled from the PV source operating condition (left-hand side of MPP, MPP, and right-hand side of MPP). Second, the possible instability occurring at the left-hand side of the MPP is eliminated. The research findings are supported by simulations and experimental results extracted out of a grid-connected inverter fed by a PV emulator. Through this testbed, the proposed controller is compared against conventional and emerging dc voltage control schemes.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据