4.4 Article

Degradation Characteristics of a 20 T REBCO Insert Magnet After a 4.2 K Standalone Test

出版社

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/TASC.2023.3254483

关键词

Superconducting magnets; Magnetomechanical effects; Degradation; Accidents; High-temperature superconductors; Electromagnetics; Voltage measurement; High-field magnet; no-insulation coils; magnet degradation; REBCO tapes

向作者/读者索取更多资源

A 20-T/17-mm HTS magnet was developed and tested, consisting of a 15-T NI REBCO insert (Coil 1) nested in a 5-T MI REBCO coil (Coil 2). The magnet experienced multiple quenches during the charging process, leading to the degradation of Coil 1. After re-warming, Coil 1 showed a significantly lower critical current. The degradation was investigated through various examinations and probable causes were proposed.
A 20-T/17-mm High-Temperature-Superconducting (HTS) magnet was developed and tested, comprising a 15-T no-insulation (NI) REBCO insert (Coil 1) nested in a 5-T metal-insulation (MI) REBCO coil (Coil 2). Coil 1 consists of 20 NI double pancakes (DP), while Coil 2 consists of 28 MI DPs. The 20-T magnet was cooled in liquid helium and charged for five runs, the maximum power supply current reached 228.7 A. Multiple quenches occurred during the charging process, causing the power supply current to drop to zero within one second. The rapid current variation induced a large voltage inside the coil, which damaged Coil 1. After re-warming, Coil 1 was tested in liquid nitrogen, and its critical current was significantly degraded. To investigate the degradation, three representative DPs from Coil 1 were examined using continuous I-c measurement and observed with optical microscope and scanning electron microscope (SEM). Most degradation areas consisted of a bubble with a current breakdown point distributed throughout Coil 1. Probable causes were proposed in this article.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据