A Parametrically Tunable Airflow Sensor Based on Electrically Coupled Resonators

期刊

IEEE SENSORS JOURNAL
卷 23, 期 20, 页码 24316-24326

出版社

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/JSEN.2023.3310271

关键词

Airflow sensor; electrical coupling; mode localization; tunable sensitivity

向作者/读者索取更多资源

This article reports a mode-localized airflow sensor with tunable parametric sensitivity using electrically coupled double-ended tuning forks. By adjusting the polarization voltage between the two resonant units, the coupling stiffness of the weakly coupled resonant system can be changed, thereby optimizing the output characteristics of the sensor. Experiment results show that reducing the polarization voltage within a certain range improves the mechanical sensitivity of the sensor, but too low or too high polarization voltage leads to severe mode aliasing or deteriorated output linearity. When the polarization voltage is set to 30 V, the tested prototype achieves high mechanical sensitivity and detection threshold.
This article reports a mode-localized airflow sensor with tunable parametric sensitivity using electrically coupled double-ended tuning forks (DETFs). By adjusting the polarization voltage between the two resonant units, the coupling stiffness of the weakly coupled resonant system can be changed, thereby optimizing the output characteristics of the mode-localized airflow sensor. The adopted electrostatic coupling method is beneficial to optimizing the mechanical sensitivity of the device on the premise of satisfying the minimum coupling stiffness condition. Both theory and experiment results demonstrated that the reduction of the polarization voltage within a certain range is conducive to improve the mechanical sensitivity of the fabricated prototype. However, when the polarization voltage is reduced below 10 V, severe mode aliasing occurs, the mechanical sensitivity is no longer significantly improved, and the output linearity deteriorates drastically. Meanwhile, when the polarization voltage is set to 30 V, the tested prototype shows a mechanical sensitivity of 2.044 x 10(-2)/(m/s)(2) and a detection threshold of 5.414 mm/s in terms of the output metric based on the subtraction of reciprocal amplitude ratios (SRARs).

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据