4.5 Article

Value of multi-channel somatosensory evoked potentials recording in patients undergoing scoliosis correction surgery

期刊

EUROPEAN SPINE JOURNAL
卷 -, 期 -, 页码 -

出版社

SPRINGER
DOI: 10.1007/s00586-023-07899-8

关键词

Somatosensory evoked potentials; Multi-channel recording; Scoliosis, Intraoperative monitoring

向作者/读者索取更多资源

This study investigated the value of intraoperative multi-channel recording of somatosensory evoked potentials (SSEPs) in patients undergoing posterior instrumentation surgery with fusion. The results showed that multi-channel SSEPs monitoring can effectively evaluate the function of the posterior column of the spinal cord, and may help to improve the success rate of monitoring and reduce the incidence of postoperative adverse events.
PurposeWe aimed to investigate the value of intraoperative multi-channel recording of somatosensory evoked potentials (SSEPs) in patients undergoing posterior instrumentation surgery with fusion.MethodsThis study included 176 patients with scoliosis who underwent posterior correction surgery from January 2019 to June 2020. Among them, 88 patients underwent routine SSEPs monitoring via single-channel (Cz'-Fpz) cortical recording (control group), while the remaining 88 patients underwent multi-channel (Cz'-Fpz and C3'-C4') SSEPs monitoring in the cortex. Chi-square and Fisher's exact tests were used to analyze the influence of age, spinal deformity classification, and Cobb angle on waveform differentiation and the success rate of SSEPs monitoring.ResultsUnivariate analysis revealed that age, type of scoliosis, and Cobb angle exerted significant effects on the success rate of intraoperative SSEPs monitoring, and the SSEPs waveform differentiation rate was poorest among patients with congenital scoliosis. Intraoperative monitoring results indicated that the success rate of single-channel SSEPs monitoring was 90.9%, while that of multi-channel monitoring was 98.9% (P < 0.05). Among the intraoperative alarm cases, the incidence of adverse events after single-channel SSEPs monitoring was 66.7%, while the incidence of adverse events after multi-channel SSEPs monitoring was only 28.6%.ConclusionMulti-channel cortical SSEPs monitoring can effectively and accurately evaluate the function of the posterior column of the spinal cord. Use of multi-channel SSEP monitoring may help to improve the success rate of monitoring and reduce the incidence of postoperative adverse events in patients with congenital scoliosis.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据