4.5 Article

Image quality of photon counting and energy integrating chest CT-Prospective head-to-head comparison on same patients

相关参考文献

注意:仅列出部分参考文献,下载原文获取全部文献信息。
Article Medicine, General & Internal

Quantum Iterative Reconstruction for Low-Dose Ultra-High-Resolution Photon-Counting Detector CT of the Lung

Thomas Sartoretti et al.

Summary: This study aimed to characterize image quality and determine the optimal strength levels of a novel iterative reconstruction algorithm for low-dose, ultra-high-resolution photon-counting detector CT of the lung. The results showed that QIR-3 provided the optimal iterative reconstruction level for low-dose, ultra-high-resolution PCD-CT of the lungs.

DIAGNOSTICS (2022)

Article Radiology, Nuclear Medicine & Medical Imaging

Comparison of image quality between spectral photon-counting CT and dual-layer CT for the evaluation of lung nodules: a phantom study

Salim A. Si-Mohamed et al.

Summary: The study evaluated the image quality of spectral photon-counting CT (SPCCT) compared to dual-layer CT (DLCT) with different reconstruction algorithms. Results showed that SPCCT had lower noise magnitude and higher detectability for nodules compared to DLCT. SPCCT provided higher image quality and better conspicuity for both ground-glass nodules and solid nodules at different iDose(4) levels.

EUROPEAN RADIOLOGY (2022)

Article Radiology, Nuclear Medicine & Medical Imaging

Dose Reduction and Image Quality in Photon-counting Detector High-resolution Computed Tomography of the Chest Routine Clinical Data

Dirk Graafen et al.

Summary: In this study, the radiation dose and image quality of Photon-counting detector computed tomography (PCD-CT) were compared with conventional energy-integrating detector CT (EID-CT) in an intrapatient comparison. The results showed that PCD-CT had similar or better objective and subjective image quality compared to EID-CT, while significantly reducing the radiation dose. Further prospective studies should be conducted to investigate the impact of these findings on clinical decision-making.

JOURNAL OF THORACIC IMAGING (2022)

Article Radiology, Nuclear Medicine & Medical Imaging

Estimating the Clinical Impact of Photon-Counting-Detector CT in Diagnosing Usual Interstitial Pneumonia

Akitoshi Inoue et al.

Summary: The study found that photon-counting detector CT provided better image quality for imaging findings of reticulation, ground-glass opacities, and mosaic pattern, enhancing radiologist confidence.

INVESTIGATIVE RADIOLOGY (2022)

Article Radiology, Nuclear Medicine & Medical Imaging

Comparison of Low Dose Performance of Photon-Counting and Energy Integrating CT

Jayasai R. Rajagopal et al.

Summary: The study showed that PCCT has superior image quality compared to EID CT at low doses, with significant improvements in image noise, contrast-to-noise ratio, and detectability index. Additionally, PCCT demonstrated higher CNR for iodine contrast at all dose levels and iodine concentration levels.

ACADEMIC RADIOLOGY (2021)

Article Radiology, Nuclear Medicine & Medical Imaging

A Clinically Driven Task-Based Comparison of Photon Counting and Conventional Energy Integrating CT for Soft Tissue, Vascular, and High-Resolution Tasks

Jayasai R. Rajagopal et al.

Summary: Photon-counting CT (PCCT) detectors show competitive advantages over energy-integrating CT (EID CT) for clinical tasks such as abdominal soft tissue imaging, vascular imaging, and high-resolution skeletal and lung imaging.

IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES (2021)

Review Critical Care Medicine

The Usefulness of Chest CT Imaging in Patients With Suspected or Diagnosed COVID-19 A Review of Literature

Stephen Machnicki et al.

Summary: The COVID-19 pandemic has had devastating medical and economic consequences globally. Chest CT imaging plays a crucial role in the management of patients with COVID-19, aiding in diagnosis, predicting disease progression, and guiding treatment. Summarizing the findings of CT scans can enhance understanding of the disease and improve patient care.
Article Radiology, Nuclear Medicine & Medical Imaging

Computed tomography with a full FOV photon-counting detector in a clinical setting, the first experience

Jiri Ferda et al.

Summary: This study evaluates the feasibility and effectiveness of using PC-CT system in body imaging of clinical patients. It shows that PC-CT provides lower radiation dose in ultra-high resolution mode, better imaging quality compared to energy integrating CT, and higher signal-to-noise ratio in both lung and abdominal imaging.

EUROPEAN JOURNAL OF RADIOLOGY (2021)

Review Medicine, General & Internal

Spectral Photon-Counting CT Technology in Chest Imaging

Salim Aymeric Si-Mohamed et al.

Summary: In recent years, the introduction of new X-ray detectors, such as photon-counting detectors (PCD) in diagnostic imaging equipment, has shown advantages in small pixel size, high dose efficiency, and energy-resolving capabilities. Studies have been conducted to explore the potential of PCD as an alternative to conventional CT for chest imaging.

JOURNAL OF CLINICAL MEDICINE (2021)

Letter Radiology, Nuclear Medicine & Medical Imaging

COVID-19 Evaluation by Low-Dose High Resolution CT Scans Protocol

Alireza Radpour et al.

ACADEMIC RADIOLOGY (2020)

Article Radiology, Nuclear Medicine & Medical Imaging

Photon-counting Detector CT: System Design and Clinical Applications of an Emerging Technology

Shuai Leng et al.

RADIOGRAPHICS (2019)

Article Radiology, Nuclear Medicine & Medical Imaging

Increasing Utilization of Chest Imaging in US Emergency Departments From 1994 to 2015

Jonathan H. Chung et al.

JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY (2019)

Article Radiology, Nuclear Medicine & Medical Imaging

Photon-Counting Computed Tomography for Vascular Imaging of the Head and Neck First In Vivo Human Results

Rolf Symons et al.

INVESTIGATIVE RADIOLOGY (2018)

Article Radiology, Nuclear Medicine & Medical Imaging

150-μm Spatial Resolution Using Photon-Counting Detector Computed Tomography Technology Technical Performance and First Patient Images

Shuai Leng et al.

INVESTIGATIVE RADIOLOGY (2018)

Review Radiology, Nuclear Medicine & Medical Imaging

Photon-counting CT: Technical Principles and Clinical Prospects

Martin J. Willemink et al.

RADIOLOGY (2018)

Article Multidisciplinary Sciences

Evaluation of a preclinical photon-counting CT prototype for pulmonary imaging

Felix K. Kopp et al.

SCIENTIFIC REPORTS (2018)

Article Radiology, Nuclear Medicine & Medical Imaging

Feasibility of Dose-reduced Chest CT with Photon-counting Detectors: Initial Results in Humans

Rolf Symons et al.

RADIOLOGY (2017)

Article Clinical Neurology

Photon-Counting CT of the Brain: In Vivo Human Results and Image-Quality Assessment

A. Pourmorteza et al.

AMERICAN JOURNAL OF NEURORADIOLOGY (2017)

Article Radiology, Nuclear Medicine & Medical Imaging

Human Imaging With Photon Counting-Based Computed Tomography at Clinical Dose Levels: Contrast-to-Noise Ratio and Cadaver Studies

Ralf Gutjahr et al.

INVESTIGATIVE RADIOLOGY (2016)

Article Radiology, Nuclear Medicine & Medical Imaging

Patient-specific quantification of image quality: An automated method for measuring spatial resolution in clinical CT images

Jeremiah Sanders et al.

MEDICAL PHYSICS (2016)

Article Radiology, Nuclear Medicine & Medical Imaging

Abdominal Imaging with Contrast-enhanced Photon-counting CT: First Human Experience

Amir Pourmorteza et al.

RADIOLOGY (2016)

Article Radiology, Nuclear Medicine & Medical Imaging

Automated Technique to Measure Noise in Clinical CT Examinations

Olav Christianson et al.

AMERICAN JOURNAL OF ROENTGENOLOGY (2015)

Review Critical Care Medicine

High-Resolution CT of Interstitial Lung Disease: A Continuous Evolution

Simon L. F. Walsh et al.

SEMINARS IN RESPIRATORY AND CRITICAL CARE MEDICINE (2014)

Article Radiology, Nuclear Medicine & Medical Imaging

Chronic Obstructive Pulmonary Disease: CT Quantification of Airways Disease

Maxime Hackx et al.

RADIOLOGY (2012)

Article Radiology, Nuclear Medicine & Medical Imaging

Pulmonary Sarcoidosis: Typical and Atypical Manifestations at High-Resolution CT with Pathologic Correlation

Eva Criado et al.

RADIOGRAPHICS (2010)