The study investigated the role of attenuation imaging (ATI) in screening potential liver donors for fatty liver detection. The results showed that ATI had good diagnostic performance and a high negative predictive value for significant fatty liver detection among potential liver donors.
Purpose: In living donor liver transplantation (LDLT), fatty liver adversely affects the outcome in donors or in recipients. The attenuation imaging (ATI) may be valuable for detecting fatty liver in potential liver donors. We aimed to investigate the role of ATI in screening liver donors. Method: In this prospective study, potential liver donors undergoing MR examination, including proton MR spectroscopy (1H-MRS), were enrolled between January 2020 and December 2021 (study identifier: KCT0004486). All participants underwent ATI examinations to assess fatty liver disease. The reference standard for fatty liver was the hepatic fat fraction (HFF) on 1H-MRS, with 8% defined as the threshold for significant fatty liver. The correlation between attenuation coefficient (AC) and HFF was evaluated using Spearman's correlation coefficient. The diagnostic performance of AC for the detection of fatty liver disease was evaluated using receiver operating characteristic curve analysis. Results: A total of 102 participants (median age, 37 [range, 20-61] years; 65 men) were enrolled. Nineteen participants (18.6%) had significant fatty liver on 1H-MRS. AC significantly correlated with HFF on 1H-MRS (& rho; = 0.674, P < 0.001), and was significantly higher in patients with HFF on 1H-MRS & GE; 8% than in patients with HFF on 1H-MRS < 8% (0.76 vs. 0.59, P < 0.001). By using the cutoff value of 0.66, the area under the curve of AC for the detection of significant fatty liver on 1H-MRS was 0.923 (95% confidence interval [CI]: 0.853-0.967), with sensitivity, specificity, and negative predictive values of 89.5% (95% CI: 66.9-98.7%), 83.1% (95% CI: 73.3-90.5%), and 97.2% (95% CI: 90.3-99.2%), respectively. Conclusions: ATI showed good diagnostic performance with a high negative predictive value for the detection of significant fatty liver among potential liver donors.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据