4.7 Article

Total-body [(68) Ga]Ga-PSMA-11 PET/CT improves detection rate compared with conventional [(68) Ga]Ga-PSMA-11 PET/CT in patients with biochemical recurrent prostate cancer

相关参考文献

注意:仅列出部分参考文献,下载原文获取全部文献信息。
Article Radiology, Nuclear Medicine & Medical Imaging

PSMA PET/CT: joint EANM procedure guideline/SNMMI procedure standard for prostate cancer imaging 2.0

Wolfgang P. Fendler et al.

Summary: This article aims to provide updated guidance and standards for the use of PSMA PET/CT in imaging prostate cancer. It discusses procedures and characteristics of various PSMA small radioligands and different clinical scenarios for their use. The document is intended to support clinicians and technicians in implementing PSMA PET/CT imaging in both research and routine practice.

EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING (2023)

Review Oncology

Head-to-head comparison of 68Ga-PSMA-11 PET/CT and 68Ga-PSMA-11 PET/MRI in the detection of biochemical recurrence of prostate cancer: summary of head-to-head comparison studies

Huasong Huo et al.

Summary: Ga-68-PSMA-11 PET/CT and Ga-68-PSMA-11 PET/MRI appear to have equivalent performance in detecting biochemical recurrence in prostate cancer.

PROSTATE CANCER AND PROSTATIC DISEASES (2023)

Article Oncology

Cancer statistics, 2022

Rebecca L. Siegel et al.

Summary: Each year, the American Cancer Society compiles data on cancer occurrence and outcomes in the United States. The latest data shows that breast and prostate cancer progress has stagnated, while lung cancer has shown improvements in survival rates. Lung cancer incidence for advanced disease has declined while localized-stage rates have increased, resulting in higher survival rates. Mortality patterns align with incidence trends, with lung cancer deaths declining rapidly, breast cancer deaths slowing, and prostate cancer deaths stabilizing.

CA-A CANCER JOURNAL FOR CLINICIANS (2022)

Article Radiology, Nuclear Medicine & Medical Imaging

Evaluation of pediatric malignancies using total-body PET/CT with half-dose [18F]-FDG

Wanqi Chen et al.

Summary: This study explored the impact of a true half dose of [F-18]-FDG on image quality in pediatric oncological patients undergoing total-body PET/CT and demonstrated that sufficient image quality and lesion conspicuity can be achieved with half-dose activity in a short acquisition time.

EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING (2022)

Article Medicine, General & Internal

Ga-68-PSMA-11 PET/CT in Patients with Biochemical Recurrence of Prostate Cancer after Primary Treatment with Curative Intent-Impact of Delayed Imaging

Jolanta Kunikowska et al.

Summary: This study evaluated the usefulness of delayed phase images in Ga-68-PSMA-11 PET/CT and found that this technique has an impact on treatment management in 16% of prostate cancer patients.

JOURNAL OF CLINICAL MEDICINE (2022)

Review Radiology, Nuclear Medicine & Medical Imaging

Total--body PET: a new paradigm for molecular imaging

Margaret E. Daube-Witherspoon et al.

Summary: Full body PET systems have revolutionized the paradigm of PET studies with their high sensitivity and ability to image multiple organs simultaneously, facing challenges and trade-offs to maximize performance gains, and potentially impacting future PET systems with new technology and concepts.

BRITISH JOURNAL OF RADIOLOGY (2022)

Article Radiology, Nuclear Medicine & Medical Imaging

Total-body PET/CT using half-dose FDG and compared with conventional PET/CT using full-dose FDG in lung cancer

Hui Tan et al.

Summary: The study aimed to explore the effects of total-body PET/CT with half-dose F-18-FDG activity on image quality, and found that the image quality in the half-dose group was better than in the full-dose group. Through subjective and objective analyses, it was discovered that the image quality scores were higher in the half-dose group, and the liver signal-to-noise ratio was significantly higher as well.

EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING (2021)

Editorial Material Radiology, Nuclear Medicine & Medical Imaging

Total-body dynamic PET/CT of micro-metastatic lymph node in a patient with lung cancer

Fangfang Fu et al.

EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING (2021)

Article Radiology, Nuclear Medicine & Medical Imaging

Combination of Forced Diuresis with Additional Late Imaging in 68Ga-PSMA-11 PET/CT: Effects on Lesion Visibility and Radiotracer Uptake

Ian Alberts et al.

Summary: This study compared traditional and modified PSMA PET/CT imaging protocols, with the new protocol incorporating additional late imaging, hydration, and forced diuresis. The results showed that the new protocol led to significantly reduced bladder activity and increased lesion uptake and contrast in late scans, improving the visibility and diagnostic accuracy of locally recurring prostate cancer.

JOURNAL OF NUCLEAR MEDICINE (2021)

Article Radiology, Nuclear Medicine & Medical Imaging

Image quality and lesion detectability in low-dose pediatric 18F-FDG scans using total-body PET/CT

Yu-Mo Zhao et al.

Summary: The study found that in pediatric patients, sufficient subjective image quality and lesion conspicuity could be maintained with a reduction in F-18-FDG administered dose to 1/30. Image noise increased significantly in 1/30 to 1/10 dose groups, while SUVmax and SD in the liver gradually increased.

EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING (2021)

Article Radiology, Nuclear Medicine & Medical Imaging

Total-Body Dynamic Reconstruction and Parametric Imaging on the uEXPLORER

Xuezhu Zhang et al.

JOURNAL OF NUCLEAR MEDICINE (2020)

Article Radiology, Nuclear Medicine & Medical Imaging

Image Quality and Semiquantitative Measurements on the Biograph Vision PET/CT System: Initial Experiences and Comparison with the Biograph mCT

Joyce van Sluis et al.

JOURNAL OF NUCLEAR MEDICINE (2020)

Article Radiology, Nuclear Medicine & Medical Imaging

Dynamic patterns of [68Ga]Ga-PSMA-11 uptake in recurrent prostate cancer lesions

Ian Alberts et al.

EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING (2020)

Article Multidisciplinary Sciences

Subsecond total-body imaging using ultrasensitive positron emission tomography

Xuezhu Zhang et al.

PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA (2020)

Article Radiology, Nuclear Medicine & Medical Imaging

The image quality, lesion detectability, and acquisition time of 18F-FDG total-body PET/CT in oncological patients

Yi-Qiu Zhang et al.

EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING (2020)

Article Radiology, Nuclear Medicine & Medical Imaging

First Human Imaging Studies with the EXPLORER Total-Body PET Scanner

Ramsey D. Badawi et al.

JOURNAL OF NUCLEAR MEDICINE (2019)

Article Radiology, Nuclear Medicine & Medical Imaging

Total-Body PET: Maximizing Sensitivity to Create New Opportunities for Clinical Research and Patient Care

Simon R. Cherry et al.

JOURNAL OF NUCLEAR MEDICINE (2018)

Article Radiology, Nuclear Medicine & Medical Imaging

Prostate Cancer Molecular Imaging Standardized Evaluation (PROMISE): Proposed miTNM Classification for the Interpretation of PSMA-Ligand PET/CT

Matthias Eiber et al.

JOURNAL OF NUCLEAR MEDICINE (2018)

Article Engineering, Biomedical

Quantitative image reconstruction for total-body PET imaging using the 2-meter long EXPLORER scanner

Xuezhu Zhang et al.

PHYSICS IN MEDICINE AND BIOLOGY (2017)

Article Radiology, Nuclear Medicine & Medical Imaging

Imaging of prostate cancer local recurrences: why and how?

Olivier Rouviere et al.

EUROPEAN RADIOLOGY (2010)