4.7 Article

Evaluation of nonlinear response biases of arch dams due to amplitude scaling via three-component record selection based on conditional spectra

期刊

ENGINEERING STRUCTURES
卷 287, 期 -, 页码 -

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.engstruct.2023.116169

关键词

Ultrahigh concrete arch dam; Vertical component hazard consistency; CS-based tridirectional record; Nonlinear response bias

向作者/读者索取更多资源

Constructing a multicomponent hazard consistency conditional spectrum (CS) is crucial for evaluating the nonlinear response of ultrahigh concrete arch dams under strong or extreme earthquakes. Neglecting the vertical (V) component hazard consistency can lead to significant biases in estimating the response dispersion of arch dams under extreme earthquakes, but has little effect on the mean response. By selecting appropriate scaling factor (SF) values, the response bias caused by neglecting V component hazard consistency can be diminished.
The nonlinear response of ultrahigh concrete arch dams under strong or even extreme earthquakes is particularly important for assessing their safety performance, which is highly dependent on the input ground motions (GMs). Based on the current China probabilistic seismic hazard analysis (CPSHA) scheme, a multicomponent hazard consistency conditional spectrum (CS) was first constructed to meet the specific hazard level at the Baihetan site; the existing issues in evaluating the seismic performance of ultrahigh arch dams via CS-based tridirectional records were then investigated. The results show that neglecting the vertical (V) component hazard consistency may result in significant biases in estimating the response dispersion of arch dams under extreme earthquakes as constraints on the V component are removed, but it has little effect on the mean response. In the CS-based tridirectional record, an excessively large scaling factor (SF) can lead to a significant overestimation of the dam's nonlinear responses because the selected record set, which is mainly composed of far-field low-amplitude records with long duration, tends to possess more energy content when scaled up than the true records. By selecting appropriate SF values (e.g., 2-5), the hazard characteristics of the selected records converge to those of the unscaled records, so the response bias of arch dams caused by neglecting the V component hazard consistency can be diminished, which provides a reference for assessing the seismic performance of structures (e.g., high arch dams) that are significantly influenced by the V component.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据