4.7 Article

Performance evaluation of a solar desalination-hot water system using heat pipe vacuum tube parabolic trough solar collector-An experimental study with Taguchi analysis

期刊

ENERGY CONVERSION AND MANAGEMENT
卷 292, 期 -, 页码 -

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.enconman.2023.117347

关键词

Solar desalination; Parabolic trough solar collector; Heat pipe vacuum tube; Taguchi-method; Design of experiments

向作者/读者索取更多资源

This study investigated a hybrid system that utilizes renewable energy to generate hot water and distilled water. The system uses a parabolic-trough heat pipe solar collector to produce hot water and provide drinking water. By increasing the temperature of the evaporator area and the condenser of the heat pipe, the system is able to directly connect to the desalination system's saltwater tank. The study evaluated the effects of water flow rate, number of heat pipes, and the filling porous medium of the vacuum tube on the system performance.
The utilization of renewable energy to generate hot water and distilled water can considerably reduce pollution. This study looked at a hybrid system that used a parabolic-trough heat pipe solar collector to generate hot water while also providing drinking water. The system is constructed in two stages, the first producing distilled water and the second producing hot water. A concave mirror increases the temperature of a vacuum tube heat pipe's evaporator area and the condenser of the heat pipe, which is directly connected to the desalination system's saltwater tank. To improve the amount of drinking water generated and to transfer thermal energy to the hot water generation system, a condenser region at the top of the saltwater tank, as well as multiple heat pipes, were employed. The effect of the water flow rate (200, 300, 400 and 500 ml/min), number of heat pipes (0, 1, 2 and 4), and the filling porous medium (0, 0.3, 0.6 and 0.9 m) of the vacuum tube on the system performance were evaluated. In addition, Taguchi-Based design of experiments was used to determine the effect of independent input parameters on the energy and efficiency of the system. The results showed that the effects of water flow rate, porous medium length, and number of heat pipes on the energy efficiency were approximately 50.89%, 26.53%, and 20.6%, respectively. Furthermore, the cost of distilled water and the cost of hot water were approximately 0.0380 $/L and 1.01 $/m3, respectively. Additionally, the highest daily productivity of the system (4940 ml/day) was obtained with a water flow rate of 200 ml/min, a length of porous media of 0.6 m, and four heat pipes. The CO2 emission reduction based on the environmental and enviroexergoeconomic parameters of the proposed systems ware improved by 37.5% and 268.4%, respectively, resulting in returns of approximately $358.1 and $260.5, respectively.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据