4.7 Article

Strategies of stable thermal output and humidity dual control for a packed-bed adsorption thermal battery

期刊

ENERGY
卷 278, 期 -, 页码 -

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.energy.2023.127978

关键词

Silica gel-based adsorbent; Packed-bed reactor; Adsorption thermal battery; Stable output performance; Temperature and humidity control; Thermal energy storage

向作者/读者索取更多资源

Water-based adsorption thermal battery (ATB) has great potential in widespread applications, especially in space heating, for energy saving and low-grade heat energy utilization. Experimental results show that the output temperature and heating power can be stabilized by tuning the airflow rate in the loop-cycle ATB system. A computational model predicts an effective heating time of 8.6 h, a discharging threshold temperature of 24 degrees C, and a maximum heat discharging efficiency of 63.4% for the packed-bed ATB. The ATB is capable of achieving stable thermal outputs for space heating applications.
Water-based adsorption thermal battery (ATB) could provide huge possibility in widespread applications; especially for space heating, leading to appreciable energy saving and low-grade heat energy utilization. A proofof-concept prototype based on composite adsorbents has been constructed to investigate the thermal performances of a packed-bed ATB. A possible strategy of tunning airflow rate for performance regulation is proposed and studied to realize stable thermal output. Additional experimental results indicated that the output temperature and heating power can be synchronously stabilized through progressive tunability of loop airflow rate in the loop-cycle ATB system. The output RH spans 40-60% along the effective discharging process, enabling a controllable humidity management in the application of direct space heating considering human thermal comfort. A three-dimensional computational model for predicting the overall thermal output performances of a packed-bed adsorption thermal battery is further developed and established. The simulation results reveal that an effective heating time of 8.6 h with a discharging threshold temperature of 24 degrees C, and an average power density of 19.3 kW m3 can be achieved with a maximum heat discharging efficiency of 63.4%. It is, therefore, apparent that the ATB is capable of achieving stable thermal outputs for space heating applications.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据