4.7 Article

A radichromic dye of tris-(4-aminophenyl)methane incorporated into polymeric films for radiation dose monitoring

期刊

DYES AND PIGMENTS
卷 217, 期 -, 页码 -

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.dyepig.2023.111387

关键词

Radiochromic film; Triphenylmethane dyes; Leuco dyes; Radiation dosimeter; High-dose dosimetry

向作者/读者索取更多资源

In this study, radiochromic films based on a radiation-sensitive dye were investigated for dose monitoring. Chlorine-containing hexachloroethane and a UV-absorber were incorporated to enhance radiation sensitivity and protect the films from light. The films exhibited a significant magenta color upon irradiation, with the intensity increasing linearly with absorbed dose. The films incorporating hexachloroethane showed higher radiation sensitivity compared to those without. The prepared dyed films have potential applications as chemical dosimeters or indicators for radiation processing.
With the goal of developing new dyed film dosimeters for radiation technology applications, radiochromic films based on tris(4-aminophenyl)methane, a radiation-sensitive dye, have been studied for dose monitoring in the dose range of 0.5-25 kGy. A chlorine-containing material, hexachloroethane, was incorporated into these films to improve their radiation sensitivity. In addition, a UV-absorber of tinuvin-P were employed to protect these films from the influence of light during storage and measurements. Subjecting these films to.-irradiation induces a significant magenta color characterized by an absorption band at 553 nm. The intensity of this band increases linearly as the absorbed dose increases up to 25 kGy and 10 kGy for compositions without and with HCE, respectively. The radiation sensitivity of the films incorporating 5.0 phr HCE is similar to 2.4 times greater than that of films without HCE. The irradiated dyed films remain stable at 6 degrees C over two months in the dark. The responses of films are relatively independent of relative humidity in the 53-75% range and temperature in the 8-34.C range. However, the films' response is temperature dependent above 34. C, thus it is advisable to calibrate these films under actual used conditions. The estimated absorbed doses using these films have an uncertainty (2 sigma) of 6.63%. In conclusion, the prepared dyed films may be good candidates for use as chemical dosimeters or indicators for applications involving radiation processing, such as food irradiation and medical sterilization.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据