Fluid-structure interactions of peripheral arteries using a coupled in silico and in vitro approach

期刊

COMPUTERS IN BIOLOGY AND MEDICINE
卷 165, 期 -, 页码 -

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.compbiomed.2023.107474

关键词

Peripheral artery disease; Blood flow; Computational fluid dynamics; Fluid-structure interaction; Cardiovascular biomechanics

向作者/读者索取更多资源

Vascular compliance, both a cause and consequence of cardiovascular disease, is important in the patency of vascular grafts. However, studying the biomechanical effects of localized changes in compliance has been challenging due to limited medical imaging technologies and surgical simulation materials. To address this, a coupled silico-vitro platform was developed to validate numerical fluid-structure interaction results with physical prototypes. The results of this study provide insights into the mechanical behavior of arterial phantoms and have promising applications in studying diseases and optimizing vascular prostheses.
Vascular compliance is considered both a cause and a consequence of cardiovascular disease and a significant factor in the mid- and long-term patency of vascular grafts. However, the biomechanical effects of localised changes in compliance cannot be satisfactorily studied with the available medical imaging technologies or surgical simulation materials. To address this unmet need, we developed a coupled silico-vitro platform which allows for the validation of numerical fluid-structure interaction results as a numerical model and physical prototype. This numerical one-way and two-way fluid-structure interaction study is based on a three-dimensional computer model of an idealised femoral artery which is validated against patient measurements derived from the literature. The numerical results are then compared with experimental values collected from compliant arterial phantoms via direct pressurisation and ring tensile testing. Phantoms within a compliance range of 1.4-68.0%/ 100 mmHg were fabricated via additive manufacturing and silicone casting, then mechanically characterised via ring tensile testing and optical analysis under direct pressurisation with moderately statistically significant differences in measured compliance ranging between 10 and 20% for the two methods. One-way fluid-structure interaction coupling underestimated arterial wall compliance by up to 14.7% compared with two-way coupled models. Overall, SolarisTM (Smooth-On) matched the compliance range of the numerical and in vivo patient models most closely out of the tested silicone materials. Our approach is promising for vascular applications where mechanical compliance is especially important, such as the study of diseases which commonly affect arterial wall stiffness, such as atherosclerosis, and the model-based design, surgical training, and optimisation of vascular prostheses.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据