Evaluation of noninvasive prenatal screening for copy number variations among screening laboratories

期刊

CLINICAL BIOCHEMISTRY
卷 118, 期 -, 页码 -

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.clinbiochem.2023.110617

关键词

Copy number variation; Microdeletion syndrome; Fetal fraction; Read depth; Noninvasive prenatal screening

向作者/读者索取更多资源

To evaluate the current situation of expanded noninvasive prenatal screening (NIPS) for copy number variations (CNVs) in laboratories in China, an external quality assessment (EQA) program was conducted. The EQA panel consisted of 12 artificial samples associated with different syndromes and was distributed to 69 laboratories. The results showed that the detection capabilities of NIPS for CNVs still need improvement and standardization.
Objective: To evaluate the current situation of expanded noninvasive prenatal screening (NIPS) for copy number variations (CNVs) in laboratories in China, the National Center of Clinical Laboratories conducted an exter-nal quality assessment (EQA) program. Methods: The EQA panel consisted of 12 artificial samples associated with different syndromes, which were mixed with maternal plasma collected from pregnant women and enzyme-digested cell-free DNA (cfDNA) from cell lines with different fetal fractions (FFs) ranging from 5% to 15%. The panel was validated by next-generation sequencing and distributed to laboratories, along with questionnaires and case scenarios. Results: Sixty-nine laboratories participated in the EQA program, and 91.30% (63/69) of laboratories correctly identified all samples. A total of 7.25% (5/69) of the laboratories reported false-negative results, and 2.90% (2/ 69) of the laboratories reported unexpected CNVs. The correct rates of the 22q11.2 deletion syndrome, Cri-du-chat syndrome, 1p36 deletion syndrome and Angelman/Prader-Willi syndrome samples were 97.46%, 98.55%, 100%, and 100%, respectively. With the increase in the FF, deletion size, and read depth, the detection rate increased. For results reports, only five laboratories reported FF values, one laboratory reported the CNV clas-sification type, and none reported sensitivity, specificity, positive predictive values, and negative predictive values. Conclusion: The detection capabilities of NIPS for CNVs still need to be improved and standardized, and FF, deletion size, and read depth are factors that affect the detection rate.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据