4.7 Article

Investigating the impact of relative humidity and air tightness on PM sedimentation and concentration reduction

期刊

BUILDING AND ENVIRONMENT
卷 241, 期 -, 页码 -

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.buildenv.2023.110270

关键词

PM; Relative humidity; Sedimentation; Aerosol; Particle size; Airtightness

向作者/读者索取更多资源

The relationship between PM and ambient humidity was evaluated through two experiments based on chemical composition and PM particle size analysis. The results showed that indoor PM concentrations were effectively decreased and prevented from spreading when the indoor relative humidity was above a certain threshold. However, increasing airtightness to increase indoor relative humidity may not be a practical solution in all cases.
Exposure to particulate matter (PM) has a negative impact on human health. The hygroscopicity of PM varies with the chemical composition and particle size, and the sedimentation trends leading to decreased PM con-centrations also vary. However, PM hygroscopicity has mostly been considered in terms of outdoor air quality such as visibility and radiation force. Thus, in this study, the relationship between PM and ambient humidity was evaluated through two experiments based on chemical composition and PM particle size analysis, which are representative PM classification methods. Firstly, six aerosols commonly found in indoor and outdoor atmo-spheres were selected, and the reduction rate of PM number concentrations by particle diameter and mass concentrations (PM10 and PM2.5) was evaluated at different relative humidity(R.H) values. The results indicated that the PM concentration was effectively decreased when indoor R.H was >70%, and the spread of PM was effectively prevented when indoor R.H was >50%. Secondly, measurements were obtained from four houses with different levels of airtightness to clarify the relationship between PM and R.H in actual living environments. Higher airtightness corresponded to lower PM concentrations due to higher R.H, but this effect was not observed when the air change rate was high. Therefore, increasing airtightness to increase R.H may not be a practical solution for reducing indoor PM concentrations in all cases. Our findings suggest that indoor air quality man-agement strategies should consider the complex interactions between PM and ambient humidity in specific building contexts.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据