4.3 Article

A novel method for continuous chromatographic separation of monoclonal antibody charge variants by combining displacement mode chromatography and step elution

期刊

BIOTECHNOLOGY PROGRESS
卷 -, 期 -, 页码 -

出版社

WILEY
DOI: 10.1002/btpr.3395

关键词

biosimilars; cation exchange chromatography; charge variants; continuous processing; monoclonal antibodies; sample-displacement

向作者/读者索取更多资源

This article presents a novel approach for the separation of charge variants during continuous CEX chromatography. By combining displacement mode chromatography and salt-based step elution, the content of acidic and basic variants is effectively controlled. Compared to traditional methods, this approach increases resin productivity and utilization, while achieving high recovery rates.
Charge heterogeneity of monoclonal antibodies is considered a critical quality attribute and hence needs to be monitored and controlled by the manufacturer. Typically, this is accomplished via separation of charge variants on cation exchange chromatography (CEX) using a pH or conductivity based linear gradient elution. Although an effective approach, this is challenging particularly during continuous processing as creation of linear gradient during continuous processing adds to process complexity and can lead to deviations in product quality upon slightest changes in gradient formation. Moreover, the long length of elution gradient along with the required peak fractionation makes process integration difficult. In this study, we propose a novel approach for separation of charge variants during continuous CEX chromatography by utilizing a combination of displacement mode chromatography and salt-based step elution. It has been demonstrated that while the displacement mode of chromatography enables control of acidic variants <= 26% in the CEX eluate, salt-based step gradient elution manages basic charge variant <= 25% in the CEX eluate. The proposed approach has been successfully demonstrated using feed materials with varying compositions. On comparing the designed strategy with 2-column concurrent (CC) chromatography, the resin specific productivity increased by 95% and resin utilization increased by 183% with recovery of main species >99%. Further, in order to showcase the amenability of the designed CEX method in continuous operation, the method was examined in our in-house continuous mAb platform.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.3
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据