Combined cooling, heat and power for commercial buildings: Optimization for hydrogen-methane blend fuels

期刊

APPLIED THERMAL ENGINEERING
卷 231, 期 -, 页码 -

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.applthermaleng.2023.120982

关键词

Combined Cooling Heat and Power; CCHP; Optimization; Clustering; Commercial loads; Hydrogen

向作者/读者索取更多资源

Considering the urgency of global warming, this study evaluates the feasibility of using a combined cooling, heat, and power system fueled with blends of hydrogen and natural gas for commercial applications in a maritime temperate climate. The system was optimized to minimize costs and greenhouse gas emissions, and compared to a conventional system using grid electrical supply and natural gas. The results show that the combined system can provide economic and emissions benefits, with potential cost savings of 5% and reduction in CO2 intensity of up to 12% when adding hydrogen to the fuel blend.
Considering the rapid pace of global warming, it is crucial to decarbonize our energy supply to meet both electric power and thermal energy demands. This study evaluates the application of a combined cooling, heat, and power system for commercial applications in a maritime temperate climate to assess the feasibility of meeting thermal and electrical demand with medium-size commercial generators fueled with blends of hydrogen and natural gas. Demand load data analysis has been conducted using open-source datasets to identify building categories with representative thermal and electrical demands. A large hospital was chosen for a representative case study to define system component capacity and operation optimization to minimize estimated costs and greenhouse gas emissions. Along with the generator, the combined cooling, heat, and power system included thermal energy storage and an absorption cooler, supplemented with conventional boiler and an electric (vapor compression) cooling system. The optimized system was compared to a conventional combination of grid electrical supply for power; cooling from an electrical chiller; and heat load from a natural gas boiler. A hierarchical clustering al-gorithm was employed to identify five representative days to cover the entire year while keeping the optimi-zation tractable. The system was sized using nested optimization, where operation over the year was optimized for a given system component sizing, then the sizing was adjusted, and the operation re-optimized in an iterative process. This ensured that the final system specification was optimized for both component size (capacity) and operation. The results show that a combined cooling, heat, and power system can provide economic and greenhouse gas emissions benefits for electricity grids with marginal CO2 intensities greater than 230-260 g/ kWh. Adding up to 50% hydrogen to the natural gas can reduce this break-even intensity by up to 12%. Net cost savings on the order of 5% can also be achieved at the break-even greenhouse gases grid intensity. Depending on the grid CO2 intensity and fuel composition, combined cooling, heat, and power can save more than 14% compared to the conventional system in 20 years.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据