4.7 Article

Study on the performance of thermoelectric refrigerator under natural convection heat transfer condition

期刊

APPLIED THERMAL ENGINEERING
卷 230, 期 -, 页码 -

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.applthermaleng.2023.120822

关键词

Thermoelectric refrigerator; Natural heat dissipation; Icepak simulation; Coefficient of performance

向作者/读者索取更多资源

This paper presents a thermoelectric refrigerator used under natural convection heat transfer conditions. Numerical simulations and experimental analyses are performed to obtain the temperature and velocity field distributions in the refrigerator chamber. The influences of the operating current and the height of fins on the temperature are analyzed. The novel design reduces the number of thermoelectric legs in a single TEC to five pairs to reduce the heat generated on the hot side during operation. The performance of TEC is improved by increasing the average heat dissipation area. The results show stable air temperature in the chamber at 12.2°C under specific conditions and an increase in temperature difference with fin's height, while the coefficient of performance (COP) remains relatively unchanged.
Refrigeration using thermoelectric cooler (TEC) is a hotspot and frontier issue, but the forced heat dissipation apparatus poses problems that limit its application. In this paper, a thermoelectric refrigerator used under natural convection heat transfer conditions is presented, and numerical simulations and experimental analyses are performed. The maximum error between the simulation results and experimental results is 6.3%. The distribu-tions of the temperature and velocity field in the refrigerator chamber are obtained, and the influences of the operating current and the height of fins on the temperature are analyzed. The novel design is that the number of thermoelectric legs in a single TEC is reduced to five pairs to reduce the heat generated on the hot side during operation. The performance of TEC is improved by increasing the average heat dissipation area. The results show that the air temperature in the chamber is finally stabilized at 12.2 & DEG;C under the ambient temperature of 29 & DEG;C and input electric power of 10.8 W. The air temperature difference inside and outside the thermoelectric refrigerator increases from 16.8 & DEG;C to 19.5 & DEG;C with the fin's height increasing, but the coefficient of performance (COP) changes little.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据