4.7 Article

Electrospun polyacrylonitrile/halloysite nanofibrous membranes for creatinine removal from kidney failure patients

期刊

APPLIED CLAY SCIENCE
卷 243, 期 -, 页码 -

出版社

ELSEVIER
DOI: 10.1016/j.clay.2023.107083

关键词

Hemodialysis membrane; Electrospinning; Creatinine; Adsorption; Halloysite

向作者/读者索取更多资源

This study demonstrates the potential of using halloysite nanotubes for creatinine adsorption in hemodialysis membranes. The composite polyacrylonitrile membranes loaded with 20 wt% of calcined halloysite nanotubes show excellent performance in creatinine removal, mechanical properties, and biocompatibility. This innovative approach has significant implications for the development of hemodialysis membranes.
Innovative hemodialysis membranes are essential for hemodialysis process, the vital clinical treatment for patients with kidney failure. In the present study, for the first time halloysite nanotubes (Hal) were applied to adsorb creatinine through molecular sieve mechanism. Firstly, calcination process performed to improve the affinity of Hal for creatinine. Afterwards, eight different composite polyacrylonitrile (PAN) nanofibrous membranes containing two types of Hal including raw Hal (RHAL) and calcined Hal (CHAL) were developed via an electrospinning device (10, 20, 30 and 40 wt%). Morphological analysis revealed that, with low contents of Hal (10 and 20 wt%), the structural integrity of nanofibers was maintained. However, with the high contents of Hal (30 and 40 wt%), structural integrity of nanofibers was affected and conical beads were formed. The mechanical properties and hydrophilicities of the composite PAN based membranes were higher than pure PAN based membrane and improved by increasing Hal contents up to 20 wt% and then reduced. Therefore, among the composite PAN based membranes, the membranes loaded with 10 and 20 wt% of Hal were selected for further evaluations. Adsorption studies showed that the composite PAN based membrane loaded with 20 wt% of CHAL had best performance with >70% of creatinine removal. The MTT assay also presented; the highest cell viability about 90% for the same membrane. Blood compatibility of the membranes for both bovine serum albumin (BSA) surface adsorption and platelet adhesion revealed that the composite PAN membranes were significantly more blood compatible than the polyethersulfone (PES) commercial and pure PAN based membranes. As a result, composite PAN based membrane loaded with 20 wt% of CHAL which combines adsorption and traditional mechanism, seems promising for hemodialysis membranes.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据