4.8 Article

PEC-SERS Dual-Mode Detection of Foodborne Pathogens Based on Binding-Induced DNA Walker and C3N4/MXene-Au NPs Accelerator

期刊

ANALYTICAL CHEMISTRY
卷 95, 期 38, 页码 14297-14307

出版社

AMER CHEMICAL SOC
DOI: 10.1021/acs.analchem.3c02529

关键词

-

向作者/读者索取更多资源

A photoelectrochemical-surface-enhanced Raman scattering dual-mode biosensor has been constructed for the sensitive and accurate detection of Staphylococcus aureus. The biosensor combines carbon nitride nanosheets and gold nanoparticles to enhance the detection performance. This study offers a novel and effective dual-mode sensing strategy with important implications for bioanalysis and health monitoring.
In this paper, a photoelectrochemical (PEC)-surface-enhanced Raman scattering (SERS) dual-mode biosensor is constructed coupled with a dual-recognition binding-induced DNA walker with a carbon nitride nanosheet (C3N4)/MXene-gold nanoparticles (C/M-Au NPs) accelerator, which is reliable and capable for sensitive and accurate detection of Staphylococcus aureus (S. aureus). Initially, a photoactive heterostructure is formed by combining C3N4 and MXene via a simple electrostatic self-assembly as they possess well-matched band-edge energy levels. Subsequently, in situ growth of gold nanoparticles on the formed surface results in better PEC performance and SERS activity, because of the synergistic effects of surface plasmon resonance and Schottky barrier. Furthermore, a three-dimensional, bipedal, and dual-recognition binding-induced DNA walker is introduced with the formation of Pb2+-dependent DNAzyme. In the presence of S. aureus, a significant quantity of intermediate DNA (I-DNA) is generated, which can open the hairpin structure of Methylene Blue-tagged hairpin DNA (H-MB) on the electrode surface, thereby enabling the switch of signals for the quantitative determination of S. aureus. The constructed PEC-SERS dual-mode biosensor that can be mutually verified under one reaction effectively addresses the problem of the low detection accuracy of traditional sensors. Experimental results revealed that the effective combination of PEC and SERS is achieved for amplification detection of S. aureus with a detection range of 5-10(8) CFU/mL (PEC) and 10-10(8) CFU/mL (SERS), and a detection of limit of 0.70 CFU/mL (PEC) and 1.35 CFU/mL (SERS), respectively. Therefore, this study offers a novel and effective dual-mode sensing strategy, which has important implications for bioanalysis and health monitoring.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据