4.7 Article

Challenges in the determination of total vitamin B12 by cyanidation conversion: insights from stable isotope dilution assays

期刊

ANALYTICAL AND BIOANALYTICAL CHEMISTRY
卷 415, 期 23, 页码 5797-5807

出版社

SPRINGER HEIDELBERG
DOI: 10.1007/s00216-023-04860-y

关键词

Cyanidation; Conversion rate; Cobalamin; Vitamin B12; Stable isotope dilution assay

向作者/读者索取更多资源

Previous methods for B12 analysis involved cyanidation conversion to determine total B12 concentration. However, this study revealed limitations associated with incomplete conversions of cobalamins during the cyanidation process. LC-MS/MS was used to detect unconverted cobalamins, but further development of a reliable monitoring method and improvement in instrument sensitivity and stability are needed to overcome the current limitations.
Previous methods for vitamin B12 (B12) analysis have extensively used cyanidation conversion with the intention of converting all cobalamins to cyanocobalamin (CNCbl) for total B12 determination. This approach has been favored for its advantages in reducing the number of analytes, increasing analyte concentration, and improving analyte stability. However, the present study revealed underlying limitations associated with this approach. First, a stable isotope dilution assay (SIDA) determining total B12 as CNCbl after cyanidation conversion (conversion SIDA method) was developed. Method validation demonstrated good sensitivity, recovery, accuracy, and reproducibility for the target analyte CNCbl. However, subsequent application of the conversion method to real meat samples showed incomplete conversions of cobalamins. These inconsistencies revealed day-to-day variability and reliability challenges associated with the cyanidation process. It was not possible to identify this issue during method validation as CNCbl was spiked as the sole analyte and it requires no further cyanidation conversion. The application of LC-MS/MS enabled the detection of trace amounts of unconverted cobalamins. Nevertheless, this approach remains restricted by instrument sensitivity and stability as well as the performance of immunoaffinity purification for different vitamers. Further development of a reliable monitoring method is a prerequisite for further optimization of the cyanidation process. However, significant improvements of analytical instrumentation in terms of sensitivity and stability are required to overcome the current limitations.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据