4.6 Article

A Radiostereometric Analysis of Tendon Migration After Arthroscopic and Mini-Open Biceps Tenodesis: Interference Screw Versus Single Suture Anchor Fixation

期刊

AMERICAN JOURNAL OF SPORTS MEDICINE
卷 51, 期 11, 页码 2869-2880

出版社

SAGE PUBLICATIONS INC
DOI: 10.1177/03635465231187030

关键词

biceps tenodesis; interference screw; all-suture suture anchor; tendon migration; biceps tendon construct

向作者/读者索取更多资源

This study aims to quantify the postoperative migration of the biceps tendon construct between arthroscopic suprapectoral BT and open subpectoral BT techniques using radiostereometric analysis. The results suggest that similar clinical outcomes can be achieved with both arthroscopic and open techniques, regardless of the type of fixation used.
Background: Studies suggest that similar clinical results are achieved via arthroscopic and open biceps tenodesis (BT) techniques. Purpose: To quantify the postoperative migration of the BT construct between arthroscopic suprapectoral BT (ASPBT) and open subpectoral BT (OSPBT) techniques via interference screw (IS) or single-suture suture anchor (SSSA) fixation using radiostereometric analysis. Study Design: Cohort study; Level of evidence, 2. Methods: Distal migration of the biceps tendon after OSPBT with a polyetheretherketone IS, OSPBT with 1 SSSA, ASPBT with polyetheretherketone IS, and ASPBT with 2 SSSAs was measured prospectively. Patients with symptomatic biceps tendinopathy and preoperative patient-reported outcome measures (PROMs) including Constant-Murley subjective, Single Assessment Numeric Evaluation, or Patient-Reported Outcomes Measurement Information System-Upper Extremity scores were included. A tantalum bead was sutured on the proximal end of the long head of the biceps tendon before fixation of tendon tissue. Anteroposterior radiographs were performed immediately postoperatively, at 1 week, and at 3 months. Bead migration was measured, and preoperative PROMs were compared with those at latest follow-up. Results: Of 115 patients, 94 (82%) were available for final follow-up. IS fixation yielded the least tendon migration with no difference between the open and arthroscopic approaches (4.31 vs 5.04 mm; P = .70). Fixation with 1 suture anchor demonstrated significantly greater migration than that achieved with an IS at both 1 week (6.47 vs 0.1 mm, 6.47 vs 1.75 mm, P < .001;) and 3 months (14.76 vs 4.31 mm, 14.76 vs 5.04 mm, P < .001) postoperatively. Two-suture anchor fixation yielded significantly greater migration than IS fixation at 1 week (7.02 vs 0.1 mm, P < .001; 7.02 vs 1.75 mm, P = .003) but not 3 months postoperatively (8.06 vs 4.31 mm, P = .10; 8.06 vs 5.04 mm, P = .07). Four patients with suture anchor fixation (3 patients in the OSPBT 1 SSSA group, 9.4%, and 1 patient in the ASPBT 2 SSSAs group, 3.8%) developed a Popeye deformity, whereas no Popeye deformities occurred in the IS groups. Mean 3-month bead migration in patients with and without a Popeye deformity was 60.8 and 11.2 mm, respectively (P < .0001). PROMs did not differ among groups at final follow-up. Conclusion: Interference screw fixation yielded the least tendon migration whether achieved arthroscopically or open. The available data indicated that fixation with 1 SSSA but not 2 SSSAs resulted in significantly greater migration than that achieved with an IS. Despite variations in tendon migration, PROMs were similar among all groups. When SSSAs are used, tendon migration may be minimized by using & GE;2 anchors.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据