In this study, a novel thermal management system based on forced air cooling with three airflow configurations is developed to explore their thermal characteristics. It was found that the axial flow configuration has the best cooling effectiveness.
Due to high heat generation within closely packed smart electronic devices, some efficient thermal management systems are required for their reliable performance, avoid overheating, long lifecycle and safety. In this study, a novel thermal management system based on forced air cooling having three airflow configurations is developed to explore the thermal characteristics of each configuration. A customized cavity is designed to have provision for three airflow configurations (axial, cross, and reverse flow) and temperature profiles are investigated within the cavity for each configuration. The experiments are performed at three heat generation rates, i.e., 10 W, 20 W, and 30 W to analyze the cooling effectiveness at a variable heat generation rate. It was observed that the maximum temperature within the setup increases with the increase in heat generation rate. In axial flow air configuration, cavity temperature has been reduced remarkably by 69 and 82.4% at 10 W and 30 W, respectively. Second to axial flow, cross flow configuration performs better than reverse flow and an overall 65.7 similar to 78.6% temperature drop is obtained compared with enclosed cavity from 10 W to 30 W, respectively. Furthermore, a similar cooling rate trend in the cavity is obtained for an increased heat generation rate in the cavity.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.1
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据