The study aimed to evaluate the correlations between right ventricular late gadolinium enhancement (LGE) at cardiac magnetic resonance (CMR) and post-pulmonary valve replacement (PVR) functional data in patients with tetralogy of Fallot (ToF). The results showed a moderate positive correlation between RV LGE score and the normalized variation of RV stroke volume, as well as a borderline moderate positive correlation between RV LGE score and the normalized variation of RV end-diastolic indexed volume.
BackgroundOur purpose was to evaluate the correlations between right ventricular (RV) late gadolinium enhancement (LGE) at cardiac magnetic resonance (CMR) in patients with tetralogy of Fallot (ToF) scheduled for pulmonary valve replacement (PVR) and post-PVR functional data.MethodsWe retrospectively reviewed ToF patients scheduled for PVR who underwent two CMR examinations at our institution, one before the procedure (CMR-0), including contrast-enhanced sequences, and one after the procedure (CMR-1). Functional left and RV data were obtained by segmenting short-axis stacks on both CMR examinations, and normalised variations were calculated by dividing differences between CMR-1 and CMR-0 by the intercurring time interval, whereas the RV scar burden was assessed on CMR-0 LGE sequences both semiquantitatively and quantitatively. Data were reported as median and interquartile range, differences were appraised with the Mann-Whitney U test, while correlations were assessed with Spearman's rho.ResultsFifteen patients with a median age of 25 years (16-29), including 9 (60%) males, with a median time interval between CMR-0 and CMR-1 of 17 months (12-23), were retrospectively reviewed. The semiquantitative LGE score at CMR-0 was 7 (6-9), and LGE volume was 4.49 mL (3.70-5.78), covering 5.63% (4.92-7.00) of the RV. RV LGE score showed a moderate positive correlation with the normalised variation of RV stroke volume (rho = 0.662, p = 0.007) and a borderline moderate positive correlation with the normalised variation of RV end-diastolic indexed volume (rho = 0.513, p = 0.050).ConclusionsThe assessment of RV LGE before PVR may provide insights on post-PVR functional data, potentially facilitating a patient-tailored treatment pathway.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

3.9
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据