3.8 Article

An Investigation on Conductive Intracardiac Communication Dynamic Channel Gain During the Cardiac Cycle for Leadless Pacemakers

出版社

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/JERM.2022.3221317

关键词

Blood volume; cardiac cycle; galvanic coupling conductive intracardiac communication; pacemakers

向作者/读者索取更多资源

This study analyzed the impact of blood volume variations during the cardiac cycle on the signal transmission of galvanic coupling conductive intracardiac communication (GCCIC) of leadless pacemakers. The in-vitro experiments showed that blood volume variations significantly affected channel gain, especially for the right ventricle-right atrium channel. The findings are important for understanding the working mechanism of leadless pacemakers.
In galvanic coupling conductive intracardiac communication(GCCIC) of the leadless pacemakers, the electrical signal transmitted directly through the myocardium and blood is inevitably affected by the cardiac cycle. Established studies focused more on the effect of the myocardium. However, our preliminary in-vitro experiments suggested that blood volume variations also significantly impacted signal transmission. In this article, we analyzed the blood volume variations during the cardiac cycle and designed an in-vitro experimental platform containing a simulated heart beating system and an automatic channel characteristic acquisition system, which controlled two peristaltic pumps to realize the periodic blood volume variations and the continuous acquisition of channel gain. Through the in-vitro porcine heart experiment, the effect of frequency and blood volume variations during the cardiac cycle on two channel gains was analyzed. Considering the impact of high-frequency signal leakage, the channel gain variations of the low frequency are the main concern. The results showed that the channel gain was positively correlated with frequency; it changed periodically with blood volume variations in the cardiac cycle, and the trends were different due to the different signal paths of the two channels. For the Right Ventricle-Right Atrium channel, the gain varied from $-67$ dB to $-53$ dB and is inversely correlated with blood volume. The gain fluctuation range was smaller for the Right Ventricle-Left Ventricle channel, about 2 dB. This study shows that the gain of intracardiac communication channels, especially the RV-RA channel, is influenced by blood volume variations during the cardiac cycle.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

3.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据