3.8 Review

Dynamic Implant Surgery-An Accurate Alternative to Stereolithographic Guides-Systematic Review and Meta-Analysis

期刊

DENTISTRY JOURNAL
卷 11, 期 6, 页码 -

出版社

MDPI
DOI: 10.3390/dj11060150

关键词

surgical navigation systems; dynamic surgery; computer-aided surgery; computer-assisted surgery; dental implant; accuracy; meta-analysis

向作者/读者索取更多资源

This research compared the accuracy of dynamic guided surgery (DGS) with static guided surgery (SGS) and freehand (FH) methods for implant placement. The results showed that there was no significant difference in accuracy between DGS and SGS, but DGS was more accurate than FH in three parameters.
(1) Background: Dynamic guided surgery is a computer-guided freehand technology that allows highly accurate procedures to be carried out in real time through motion-tracking instruments. The aim of this research was to compare the accuracy between dynamic guided surgery (DGS) and alternative implant guidance methods, namely, static guided surgery (SGS) and freehand (FH). (2) Methods: Searches were conducted in the Cochrane and Medline databases to identify randomized controlled clinical trials (RCTs) and prospective and retrospective case series and to answer the following focused question: What implant guidance tool is more accurate and secure with regard to implant placement surgery? The implant deviation coefficient was calculated for four different parameters: coronal and apical horizontal, angular, and vertical deviations. Statistical significance was set at a p-value of 0.05 following application of the eligibility criteria. (3) Results: Twenty-five publications were included in this systematic review. The results show a non-significant weighted mean difference (WMD) between the DGS and the SGS in all of the assessed parameters: coronal (n = 4 WMD = 0.02 mm; p = 0.903), angular (n = 4 WMD = -0.62 & DEG;; p = 0.085), and apical (n = 3 WMD = 0.08 mm; p = 0.401). In terms of vertical deviation, not enough data were available for a meta-analysis. However, no significant differences were found among the techniques (p = 0.820). The WMD between DGS and FH demonstrated significant differences favoring DGS in three parameters as follows: coronal (n = 3 WMD = -0.66 mm; p =< 0.001), angular (n = 3 WMD = -3.52 & DEG;; p < 0.001), and apical (n = 2 WMD = -0.73 mm; p =< 0.001). No WMD was observed regarding the vertical deviation analysis, but significant differences were seen among the different techniques (p = 0.038). (4) Conclusions: DGS is a valid alternative treatment achieving similar accuracy to SGS. DGS is also more accurate, secure, and precise than the FH method when transferring the presurgical virtual implant plan to the patient.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

3.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据