3.9 Article

Assay of iodine monochloride via iodination of 2-chloroaniline using reversed-phase liquid chromatography

期刊

SEPARATION SCIENCE PLUS
卷 6, 期 5, 页码 -

出版社

WILEY-V C H VERLAG GMBH
DOI: 10.1002/sscp.202200146

关键词

2-chloro-4-iodoaniline; 2-chloroaniline; iodine monochloride; N-chloro-N-(phenylsulfonyl)benzenesulfonamide; Wijs solution

向作者/读者索取更多资源

Recent studies have reported the mono-iodination of 2-chloroaniline in the presence of iodine monochloride. A new HPLC method has been developed for the assay of iodine monochloride using a reversed-phase C18 column and gradient elution with water and acetonitrile as mobile phase. The method showed good linearity and accuracy, with precision within 1%, and was successfully applied to determine the assay of commercially available iodine monochloride and in-situ generated samples.
Iodine monochloride is conventionally determined using the sodium thiosulphate titration method. Recently, mono-iodination of 2-chloroaniline in N,N-dimethylformamide has been reported in the presence of iodine monochloride. A reversed-phase high-performance liquid chromatography method for the assay of iodine monochloride on the C18 column has been developed via the iodination of 2-chloroaniline. Chromatographic separation was achieved using gradient elution with water and acetonitrile as mobile phase at 1 ml/min flow rate and detection at 304 nm. The elution of 2-chloro-4-iodoaniline was observed at 5.492 min. Under the given experimental conditions, an excess of 2-chloroaniline dissolved in acetonitrile reacted with a known amount of pure iodine monochloride resulting in 2-chloro-4-iodoaniline. The amount of 2-chloro-4-iodoaniline formed is a measure of the initial iodine monochloride concentration, thus providing the assay of iodine monochloride. The method was validated as per the guidelines of the International Conference on Harmonization guidelines and found to be linear (r(2) = 0.999) and accurate (98%-102%) for iodine monochloride concentrations ranging from 0.4 to 1.2 mg/ml. The intra-day and inter-day precision were within 1%. The validated method was successfully applied to determine the assay of commercially available iodine monochloride, Wijs solution, and in-situ generated iodine monochloride samples. Thus, a novel, simple, accurate, and precise HPLC method has been developed for iodination monochloride assay.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

3.9
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据