4.5 Article

Method development for simultaneous estimation of Amlodipine Besylate and Perindopril Tertbutyl amine in fixed-dose

期刊

HELIYON
卷 9, 期 3, 页码 -

出版社

CELL PRESS
DOI: 10.1016/j.heliyon.2023.e14209

关键词

Amlodipine Besylate (ADB); Perindopril Tertbutylamine (PTBA); Fixed -dose; Method development

向作者/读者索取更多资源

This study developed a new reverse-phase liquid chromatography method to simultaneously analyze the content of Amlodipine Besylate and Perindopril Tertbutylamine in mixed tablets. The results showed that this method is accurate and reliable. This is the first time that high-performance liquid chromatography has been used in a time-efficient and cost-effective way to simultaneously identify and quantify Amlodipine Besylate and Perindopril Tertbutylamine.
The fixed-dose combination of Amlodipine Besylate (ADB) with Perindopril Tertbutylamine (PTBA) drug is used to treat patients with mild-to-moderate hypertension. In recent times re-searchers are interested to find the efficient analytical method development and validation for the simultaneous determination of ADB and PTBA in a fixed-dose, film-coated tablet. Therefore, the current study was performed with a reverse-phase liquid chromatography method developed to simultaneously analyze ADB and PTBA in film-coated tablets as fixed-dose combinations. The linearity of the proposed method was calculated by preparing six different mixtures of both ADB and PTBA in the mobile phase. The concentration of both the analytes was analyzed at 56mg/100 mL to 84mg/100 mL and 32mg/100 mL to 48mg/100 mL, respectively. The ratio of acetonitrile and phosphate buffer was 35:65. The flow rate was adjusted to 1.5 ml per minute to reduce the retention time. The validation study was performed for the parameters specificity, linearity, precision, range, limit of detection, limit of quantification, accuracy/biasness, and robustness. The relative percentage standard deviation for Perindopril Tertbutyl amine was 0.148%, and for Amlodipine is 0.312%. These results show that the advanced analysis method for simultaneous analysis of fixed-dose is precise. The theoretical IR spectra were also calculated by Gaussian 9.2 by employing the B3LYP functional at density functional theory (DFT) level study. All these parameters studied in this work authenticate the effectiveness of the developed validation method and ensure its repeatability/reproducibility accordingly. To the best of our knowledge, this is the first time to develop a new fast, and easy method for simultaneous identification and quantifi-cation of ADB and PTBA by high-performance liquid chromatography (HPLC) with a time -efficient and cost-effective approach.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据